en
8
Installation
Indications,
functions and options
Messages
Operation and function
Display channels
Channel
Description
Connection
terminal
Page
COL
x
Temperature collector
S1
11
TST
x
Temperature store
S2
11
S3
x
Temperature sensor 3
S3
11
TR
x*
Temperature return sensor
S3
11
n %
x
Speed R1
R1
11
hP
x
Operating hours R1
R1
11
kWh
x*
Heat quantity in kWh
-
11
MWh
x*
Heat quantity in MWh
-
11
Adjustment channels
Channel
Description
Factory setting
Page
DT O
x
Switch-on temperature difference
6.0 K
12
DT F
x
Switch-off temperature difference
4.0 K
12
DT S
x
Set temperature difference
10.0 K
12
RIS
x
Rise
2 K
13
S MX
x
Maximum store temperature
60 °C
13
EM
x
Collector emergency temperature
130 °C
13
OCX
x
Collector cooling option
OFF
14
CMX
x*
Maximum collector temperature
110 °C
14
OCN
x
Collector minimum limitation option
OFF
14
CMN
x*
Collector minimum temperature
10 °C
14
OCF
x
Antifreeze option
OFF
14
CFR
x*
Antifreeze temperature
4.0 °C
14
OREC
x
Recooling option
OFF
15
O TC
x
Tube collector option
OFF
15
OHQM
x
Heat quantity measurement option
OFF
15
FMAX
x*
-AXIMUMmOWRATE
6.0 l
15
MEDT
x*
Antifreeze type
1
15
MED%
x*
Antifreeze concentration
(only if MEDT = propylene or ethylene glycol)
45 %
15
nMX
x*
Maximum speed relay 1
100 %
16
nMN
x
Minimum speed relay 1
30 %
16
MAN
x
Manual mode R1
Auto
16
LANG
x
Language
dE
16
VERS
Version number
Legend:
Symbol
Description
x
Channel is available
x*
Channel is available, if the corresponding option is activated.
Summary of Contents for DeltaSol BS/2 HE