Installation
Indications,
functions and options
Messages
Operation and function
5 Channel overview
5.1 Display channels
Note:
The display and adjustment channels as well as the adjustment ranges de-
pend on the functions and options as well as on the system components
connected to the controller.
Display of collector temperatures
COL
Collector temperature
Display range: -40 … + 260 °C
Indicates the collector temperature.
Display of store temperatures
TST
Store temperature
Display range: -40 … + 260 °C
Indicates the store temperature.
Display of sensor S3
S3
Sensor temperature
Display range: -40 … + 260 °C
Indicates the current temperature at the additional sensor (without control function).
Note:
Only if a sensor is connected to the corresponding terminal, will a value
be displayed.
Indication of return temperature
TR
Return temperature
Display range: -40 … + 260 °C
If the heat quantity measurement is activated, the temperature at sensor S3 will be
indicated as TR.
Indication of current pump speed
n %
Current pump speed
Display range: 20 … 100 %
Indicates the current pump speed.
Display of heat quantity
kWh / MWh
Heat quantity in kWh / MWh
Display channel
Indicates the heat quantity produced in the system. For this purpose, the heat quan-
TITYMEASUREMENTOPTIONHASTOBEENABLED4HEmOWRATEASWELLASTHEVALUESOF
THEREFERENCESENSORSmOWANDRETURNAREUSEDFORCALCULATINGTHEHEATQUANTITY
supplied. It is shown in kWh in the
kWh
channel and in MWh in the
MWh
channel.
The overall heat quantity results from the sum of both values.