1.  The installation and repair of this appliance must be 

done by a qualified service person. Failure to properly 

install and maintain this heater could result in an 

unsafe or hazardous installation, which may result in 

a fire, explosion, property damage, personal injury or 

loss of life. 

2.  This appliance should be inspected before use and 

at least annually. More frequent cleaning may 

be required due to excessive lint from carpeting, 

bedding material, pet hair, etc. It is imperative that 

control compartments, burners and circulating air 

passageways of the appliance be kept clean.

  `S’assurer que le bruleur et le compartiment des com-

mandes sont propres. Voir les instructions d’installation 

et d’utilisation qui accompagnent l’appareil.

3.  This appliance may be installed in an aftermarket 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes.  

This appliance is only for use with the type(s) of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used. 

  Cetappareil peut être installé dans un maison préfab-

riquée (mobile) déjà installée à demeure si les règle

-

ments locaux le permettent.

  Cet appareil doit être utilisé uniquement avec les 

types de gas indiqués sur la plaque signalétique. Ne 

pas l’utiliser avec d’autres gas sauf si un kitde conver-

sion certifié est installé.

4.  The installation must conform to local codes. Your lo-

cal Scan authorized dealer can assist you in determin

-

ing what is required in your area for a safe and legal 

installation. Some areas require a permit to install 

a gas burning appliance. Always consult your local 

building inspector or authority having jurisdiction to 

determine what regulations apply in your area. 

  In the absence of local codes, the installation require-

ments must comply with the current National codes. 

In the U.S., these requirements are established in the 

National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, 

the codes have been established in CAN/CGA B149 

Fuel Installation Code. 

  Installer l’appareil selon les codes ou reglements 

locaux, ou, en l’absence de tels reglements, selon les 

Codes d’installation CAN/CGA-B149.

5.  Do not operate this fireplace if any part of it has 

been under water.

  Immediately call a qualified service technician to 

inspect the heater and to replace any part of the 

control system and any gas control which has been 

under water.

  Ne pas se servir de cet appareil s’il a ete’ plonge dans 

l’eau, completement ou en partie.  Appeler un tech-

nicien qualifie pour inspecter l’appareil et remplacer 

toute partie du syste’me de controle et toute com-

mande qui ont ete plonges dans l’eau.

6.  Do not operate the fireplace with the glass front re

-

moved, cracked or broken. Replacement of the glass 

should be done by a licensed or qualified service 

person.  Only remove glass for routine service. Always 

handle glass carefully.

  Pour utilisation avec les portes en verre cerifiers aved 

l’appareil seulemend ou. Ne pas utiliser avec des 

portes on verre. 

7.  Notify your insurance company before proceeding 

with installation of this fireplace.

THIS HEATER MUST BE INSTALLED AND MAIN

-

TAINED BY A QUALIFIED SERVICE AGENCY.  

DO NOT ATTEMPT TO ALTER OR MODIFY THE 

CONSTRUCTION OF THIS APPLIANCE OR ITS COM-

PONENTS. ANY MODIFICATION OR ALTERATION 

WILL VOID THE WARRANTY, CERTIFICATION AND 

LISTING OF THIS APPLIANCE.

Your fireplace insert has a unique serial number 

stamped on the rating plate which is located in the valve 

compartment. Please record the serial number in the 

space below. You may also wish to attach your purchase 

receipt to this page for future reference.

MODEL NAME:   Scan 45i TSI Direct Vent Gas Fireplace 

Insert

SERIAL NUMBER:_______________________________

 

DATE OF PURCHASE:____________________________

AUTHORIZED DEALER:__________________________

 

 

   ADDRESS ___________________________________

 

 

   PHONE: ____________________________________

   INSTALLER:__________________________________

 

FUEL TYPE:____________________________________

FUEL CONVERSION:                  NO _______       YES_____

NOTES:________________________________________

______________________________________________

______________________________________________

Summary of Contents for Scan 45i TSI

Page 1: ...aucum interrupteur Ne pas vous servir des t l phones se trou vant dans le b timent o vous trouvez Appelez imm diatement votre fournis seur de gaz depuis un voisin Suivez les instructions du fournisseu...

Page 2: ...d Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructions must remain with the appliance or equipment at the completion of the installat...

Page 3: ...Starfire Glass Embers or Tumbled Stone burner media is packaged separately from the insert firebox Figure 1 Pull each Trunk Latch down to disengage it from the Glass Frame Glass Frame Latch Locations...

Page 4: ...s fireplace in sert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21 88 2009 CSA 2 33 2009 CAN CGA 2 17 M91 and CSA P 4 01 2 for Canada Starfire Glass Ember Kit...

Page 5: ...the codes have been established in CAN CGA B149 Fuel Installation Code Installer l appareil selon les codes ou reglements locaux ou en l absence de tels reglements selon les Codes d installation CAN...

Page 6: ...burns or clothing ignition Enfants et adultes doivent tre avertis des dangers des temp ratures de surface lev es et devraient rester l cart pour viter les br lures ou l inflammation des v tements Youn...

Page 7: ...ials Figure 2 Firebox dimensions Leg Leveling Bracket Note Two right and left brackets are factory installed The brackets allow the insert to be raised up to 2 1 2 off of the hearth Also note that use...

Page 8: ...imum 18 forward of the firebox glass panel Raised Hearth A raised hearth that is at least 6 high requires a non combustible hearth that extends a minimum 12 from the fireplace glass and and is a minim...

Page 9: ...Figure 5 Baseline Mantel and Trim clearance requirements The insert is raised 2 on the leveling brackets Leg Leveler Bolts and Brackets This feature enables greater installation flexibility beyond el...

Page 10: ...3 M99 TEST METHODS AND RESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Vent Guidelines All vent compo...

Page 11: ...ct to the insert 9 Compress the ducts so that they are hanging above the height of the fireplace opening and are out of the way 10 Position the insert without surround panels half way inside the firep...

Page 12: ...ESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Figure 9 Venting through prefabricated fireplace chimn...

Page 13: ...is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D Attach the Fireplace Conversion Notice to the back of the fireplace if appropriate 9 Surrou...

Page 14: ...ARY MANIFOLD PRESSURES inches water column MIN MAX NATURAL GAS 1 6 WC 3 5 WC PROPANE 5 3 WC 11 0 WC ALWAYS TEST PRESSURE WITH THE VALVE REGULATOR ADJUSTED TO THE HIGHEST SETTING Figure 11 Gas connecti...

Page 15: ...ilot rectification and or frequent burner outages Little variation in flame picture between HI and LO regulator settings Insufficient gas to support more than one ap pliance causing nuisance outages o...

Page 16: ...TABLIS DANS LES IN STRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L EQUIPEMENT Conversion Kit LP 157249 NG 157250 Tools required 1 2 13 mm open end wrench or deep well socket Torx T20 driver 1 4 nut dr...

Page 17: ...ould not be able to move to the right or left 10 Replace the variable regulator on the gas control valve Remove the TruStart switch faceplate and move the assembly out of the way to access the regulat...

Page 18: ...aller and applied to the appli ance at the time of the conversion See fig 19 Derating procedure 1 Turn off gas supply to the appliance and disconnect from electrical power source 2 Remove the Glass Fr...

Page 19: ...ing the air shutter will generate a flame that is blue and transparent or an anemic flame This flame is generally more efficient but not very attractive We recommend the following settings for the Sca...

Page 20: ...shutter See figs 14 and 15 pages 16 17 4 Use a 10 mm socket to remove the left and right burner bracket nuts Remove the Burner Bracket from the firebox See fig 23 5 Bend the two upper rear tabs down...

Page 21: ...ure 26 Install Glass Embers Tumbled Stones Kit 157245 NOTE Install the optional Reflective Glass Panels before installing the stones Spread the stones evenly around the burner media tray CAUTION Take...

Page 22: ...mote Control connections GREEN GRAY The optional J tul Remote Control can be used with the Scan 45i TSI however the receiver must be installed outside of the firebox cabinet If there is no room for it...

Page 23: ...mable Backing Plate Front Assembly Riser Bar Leveling Brackets Standard Ventilated Control Door Optional Full Panel Control Door NOTE THE OPTIONAL FULL PANEL CONTROL DOOR MAY ONLY BE USED IN CONJUNCTI...

Page 24: ...r remote calls for heat the PREHEAT lamp will indicate Draw Collar warm up Pilot ignition occurs after approximately two to three minutes or when the vent is sufficiently heated to induce draft follow...

Page 25: ...dy not lifting or float ing The flame should be blue in color around the pilot hood with traces of yellow toward the outer edges It is important that the pilot flame engulf the top 1 8 of the flame re...

Page 26: ...ems 22 and 24 fig 39 on page 27 Use four AA batteries noting the polarity indicated on the box Glass Care Moisturecondensationisanormaloccurrencewithgasappli ancesandparticulateaccumulationmayappearon...

Page 27: ...onnectors 3 8 O D x 24 21 223953 Valve Bracket 22 22410792 Heat Shield Battery Box 23 117975 Wing Nut M6 Zinc 24 22426292 Battery Holder w cover 4 AA 25 223901 Heat Shield Valve 26 222280 Gasket Drop...

Page 28: ...0 F No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk Oxide 2 222799 Blower Bracket 3 222072 Blower TransFlow 12 Cage 120 CFM No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 S...

Page 29: ...H WH M 1 3 2 4 5 6 7 8 9 10 GY GN GN BK BK BK TAN TAN BK WH BK WH BL GN BK BK BK RD BK RD BK RD BK GN YL GN BK YL GN GN OR GN TAN 13 12 TAN WH 11 14 BK BK BK WH BK TAN TAN TAN TAN NOTE Circled numbers...

Page 30: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Page 31: ...Never use tools If the knob will not turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any pa...

Page 32: ...lation it is important that these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification color or typ...

Reviews: