11
4.0
Adjustment and treatment
Painting the surround
All surrounds are delivered unpainted.
Painting may take place the day after installation. Use latex
paint. If a slight surface texture is desired mix a little tile cement
in with the paint.
Cracks
After several month’s usage small cracks may appear in the joints
due to settling. These cracks can easily be repaired:
• Open up the cracks with, for example a screwdriver, in order
to give more space for the filler.
• Remove any dust with a vacuum cleaner.
• Inject an acrylic filler into the cracks and smooth over with a
wet soapy finger.
• After a couple of days the join may be painted.
5.0
Assembly of the surround
The Jøtul S
43
W comprises the following
parts, see fig. 3A and 3B:
Part 1.
Blocks
Part 2.
Base
Part 3.
Side vents
Part 4.
Side panels
Part 5.
Cowling
Part 6.
Top grid
Install the insert as described in the installation and user
instructions (cat. no. 129543) that are included with the product.
The height from the floor to the bottom front list of the insert is
about 430 mm.
It is recommended that prior to permanently attaching the insert
to the chimney the surround is mounted dry in order to be able to
make any adjustments.
Remember!
Use the acrylic glue provided for all joints and against
the wall.
Installation in front of a straight wall (fig.
4A) and corner installation (fig. 4B)
N.B. The entire floor under the surround must be covered by a
steel plate.
1. Place the four seating washers on top of the blocks (part 1).
2. Then place the insert on top of the blocks in accordance with
the distances shown in
figure 2
.
3. Tilt the insert a little towards the back and push the base on
the inside of the frontlist and against the wall. Make sure
that there will be a 1-2 mm space between the insert and the
surround
4. Using a spirit level correct any crookedness with glue, mortar
or small steel washers. It is imperative that the base is stable
and level.
5. Mount the side panels (part 4). Ensure that the insert is
centred in relation to the side panels and base. Mount the
panels behind the surround frame and glue them to the wall.
Allow approximately 1-2 mm clearance between the plates
and the surround. If necessary, use the adjusting screws on
the insert legs.
N.B. Remember to use glue between all parts.
Mark where the hole in the chimney is to be located and mount
the flue insert and flue pipe according to regulations. If using a
top-mounted flue pipe cut an opening in the top grid.
N.B. Remember that there shall be a minimum incline of 2%
towards the chimney.
6.
Mount the cowling (part 5) and glue it to the side panels and
firewall.
7.
Place the top grid (part 6) in position over the opening.
For Jøtul S 43 C
: use a nail to attach the grid to the wall.
8.
Fasten the side vents using acrylic glue.
ENGLISH
Summary of Contents for S 43 C
Page 19: ...19 Fig 1 Fig 2...
Page 20: ...20 Fig 3A Fig 3B Fig 4A Fig 4B...
Page 21: ...21 Fig 7 Fig 5 Fig 6 A B...
Page 22: ...22...
Page 23: ...23...