background image

16

ENGLISH

5.0 Assembly 

The Jøtul S 

16 

C/W comprises the following parts, 

(fig. 3A+3B)

Part 1.  Base plate
Part 2.  Base
Part 3.  Support plate,
Part 4.  Bench plate - tripartite, slate
Part 5.  Small side panels, 2 pcs. 
Part 6.  Side panels, 2 pcs.
Part 7.  Cowling
Part 8.  Side valves, 2 pcs. 
Part 9.  Steel plate 
Part 10. Rockwool
Part 11.  Top sections, 2 pcs.
Part 12. Short legs, 3 pcs.
Part 13.  Back panel, base 

(corner installation only)

Floor plate and shelf (marble) must be ordered separately.

The product is heavy! You will need help during assembly. 

Assemble the insert as described in the installation and user 
instructions (cat. no. 128975) that are included with the product.

It is recommended that prior to permanently attaching the insert 
to the chimney, the surround is mounted dry in order to be able 
to make any adjustments.

Because of different ceiling heights, the height of the surround 
must be adjusted:

•  The surround should be finished min. 20 mm from the 

ceiling. 

•  If necessary, cut off a little from the top section. 

Use the enclosed acrylic paste for all joints.

 

5.1 For Jøtul S 

16

  C

1.  Place the base plate 

(part 1)

.

2. Place the base 

(part 2)

 in position flush with the wall. Using 

a spirit level correct any crookedness with glue, mortar or 
small steel washers. It is imperative that the base is stable 
and level.

3.  Place the back panel base 

(part 13)

 and glue it to the wall.

4.  Place the support plate 

(part 3)

.

5.  Unpack the insert. Take out the loose parts to make the 

product less heavy. Also remove the ash lip and the bottom 
frame situated at the rear of the combustion chamber. Close 
the doors.

Assembly of the legs:

6.  Place the wooden pallet and the cardboard packaging on the 

floor and lay the fireplace carefully down on its back. Unscrew 
the 3 screws which are screwed onto the underside of the 
fireplace 

(fig. 4)

.

7. 

Note! The cast iron legs are not to be used.

 

Attach the 3 short legs 

(part 12)

 by using the screws from the 

underside of the fireplace. (Use the unthreaded holes.) 

(Fig. 4A).

8.

 

Screw the adjusting screws M10x45mm 

(fig. 4B) 

onto the short 

legs.  The screw heads should be facing downwards to fit into 
the grooves in the bracket 

(fig. 4C).

 Screws and brackets are 

delivered with the insert. 

9.  Stand the combustion chamber up.
10. Place the insert on the support plate 

(part 3)

. Position the 

brackets under the screw heads 

(fig. 4C)

 to protect the surface 

and to prevent the insert from slipping out of place. 

Fitting the bottom frame 

(Jøtul I 

80

 Harmony og Panorama):

11.  Remove the knob on the bar for the lower air vent 

(fig. 5A)

.

12. Place the bottom frame 

(fig. 5B)

 so that the bar passes through 

the hole in the frame.

13. Fasten the bottom frame with 2 screws M6x12 mm 

(fig. 5C) 

and refit the knob.

Assembly of the flue connecting pipe:

14. The flue connecting pipe 

(fig. 6A)

, which is packed in the 

box, shall be placed on the top of the fireplace. Place the flue 
connecting pipe in such a manner that the screw attached to 
it 

(fig. 6D)

, is facing outwards.

15. Place one clamp iron 

(fig. 6B)

 on each side. Fasten with a screw 

M8x30mm and a nut 

(fig. 6C)

.

16. Place the marble bench plate 

(part 4)

.

17.  Test mount the side panels 

(part 6)

 

and 

the small side panels 

(part 5).

 Make sure that the insert is centred in relation to the 

side panels and the base. There should be approximately 1-2 
mm between the panels and the insert. If necessary, use the 
adjusting screws on the insert legs. 

Remember that the ash 

lip is not mounted! 

18. Remove the side panels.
19. Mark where the hole in the chimney is to be located and mount 

the flue insert and flue pipe according to regulations.

 

Remember that there shall be a minimum incline of 2% towards 
the chimney.

20. Mount the side panels 

(part 6)

 and the small side pane

ls 

(part 

5)

 behind the insert frame and glue them to the wall. 

21.  Place and adjust the cowling 

(part 7)

.

22. Mount the two valves 

(part 8)

 on each side of the cowling 

and fasten them with acrylic glue. The valve openings must 
be facing foreward. 

23. Lay first the steel plate and then the rockwool 

(part 10)

 over 

the opening on top of the cowling. If steel chimney is to be 
used, see point «

5.3 Steel chimney».

24. Place the two top sections 

(part 11)

There must be an opening 

of min. 20 mm between the top section and the ceiling.

Summary of Contents for S 16 C/W- I 80

Page 1: ...nces Wir empfehlen Ihnen die Montage und Bedienungsanleitung f r sp tere Zwecke sorgf ltig aufzubewahren J tul S 16 C W I 80 Manual version P07 NO Montering og bruksanvisning 2 SE Montering och bruksa...

Page 2: ...ltet for installasjonen er festet p innsatsens skjermplate Det inneholderinformasjonomidentifikasjonogdokumentasjon av produktet 2 0 Tekniske data Se fig 1A 1B 1C Omrammingen er tilpasset J tul I 80 M...

Page 3: ...ateriale Forplaten m v re i henhold til nasjonale lover og regler For Norge Min 300 mm fremfor ileggs pning og bredde minimum lik ileggs pningen Kontakt dine lokale bygningsmyndigheter ang ende restri...

Page 4: ...Fig 4A 8 Stillskruene M10 x 45 mm fig 4B festes i hullet med gjenger Skruehodeneskalvendenedfor passeisporiunderlagsbrikke fig 4C Skruer og brikker f lger innsatsen 9 Reis brennkammeret opp 10 Plasse...

Page 5: ...roller at innsatsen st r sentrert i forhold til sidevanger og sokkel Det skal v re ca 1 2 mm klaring mellom vanger og innsats Juster evt justeringsskruene p beina til innsatsen Husk ta hensyn til l s...

Page 6: ...rvice osv Typskylten f r installasjonen finns p insatsens sk rmpl t Den inneh ller uppgifter om identifikation och dokumentation av produktet 2 0 Tekniska data Se fig 1A 1B 1C Omramningen anpassas f r...

Page 7: ...m ste uppfylla kraven enligt nationala lagar och f reskrifter F r Sverige Hela golvet under eldstaden min 300 mm framf r d rren och 100 mm p vardera sidan m ste t ckas Kontakta l mplig myndighet f r...

Page 8: ...A med skruvarna fr n insatsens undersida f stes genom h len utan g ngar 8 St llskruvarnaM10x45mm fig 4B skruvasfast genomh len medg ngar Skruvhuvudenaskav ndasned tf rattpassaisp ri underl ggsbricka f...

Page 9: ...rna del 5 Kontrollera att insatsen r centrerad i f rh llande till sidostyckerna och sockeln Det ska vara ca 1 2 mm mellan sidostyckerna och insatsen Anv nd justeringsskruvarna p insatsens ben om s beh...

Page 10: ...etaan takkasyd men mukana Siit l ytyv t turvaohjeet sek p ivitt ist k ytt hoitoa ja huoltoa koskevat ohjeet Tuotteen takana olevaan suojapeltiin kiinnitetty kuumuudenkest v st materiaalista valmistett...

Page 11: ...stettu levy Etulevyn syvyys on v hint n 300 mm Syvyys m r ytyy kunkin maan voimassa olevien m r ysten mukaisesti Kysy asennusta koskevia vaatimuksia ja rajoituksia paikallisilta rakennusviranomaisilta...

Page 12: ...joissa ei ole kierteit Kuva 4A 8 Kiinnit s t ruuvit M10 x 45 mm kuva 4B reikiin joissa on kierteet Ruuvien p iden on tarkoitus sopia aluslevyiss oleviin koloihin kuva 4C Ruuvit ja aluslevyt toimiteta...

Page 13: ...5 Katso ett takkasyd n on keskell suhteessa sivuseiniin ja sokkeliin Sivuseinien ja takkasyd men v lisen et isyyden tulee olla n 1 2 mm S d takkasyd menkorkeutta tarvittaessajalkojens t ruuveilla Muis...

Page 14: ...heat shield at the back of the insert This contains information about identification and documentation for the product 2 0 Technical data See fig 1A 1B 1C The surround is adapted to suit the J tul I 8...

Page 15: ...mmable material should be used The size of the plate should be according to the laws and regulations in each country Contact your local building authority regarding restrictions and installation requi...

Page 16: ...headjustingscrewsM10x45mm fig 4B onto theshort legs The screw heads should be facing downwards to fit into the grooves in the bracket fig 4C Screws and brackets are delivered with the insert 9 Stand t...

Page 17: ...is centred in relation to the side panels and the base There should be approximately 1 2 mm between the panels and the insert If necessary use the adjusting screws on the insert legs Remember that the...

Page 18: ...Ein Typenschild aus hitzebest ndigem Material befindet sich auf dem Hitzeschild an der R ckseite des Einsatzes Es enth lt Informationen ber Kennzeichnung und Dokumentation des Produkts 2 0 Technische...

Page 19: ...entsprechen Bei der rtlichen Baubeh rde erhalten Sie Informationen zu Einschr nkungen und Auflagen bei der Aufstellung 3 5 Standardanforderungen an Deckenschutz Ist dieOfenverkleidungbiszurDeckegemau...

Page 20: ...l 3 Die Halterungen Abb 4C mu zum Schutz der Oberfl che und um zu verhindern da der Einsatz wegrutscht unter den Schraubenk pfen plaziert werden EinbaudesunterenRahmens J tulI80HarmonyundPanarama 11 E...

Page 21: ...n Sie die untere Simsplatte in Marmor aus Teil 4 16 Die Seitenbleche Teil 6 und Verl ngerungsst cke Teil 5 probeweiseaufstellen Vergewissern Sie sich dass den Einsatz in Bezug auf die Seitenbleche und...

Page 22: ...u erzielen sollte die Ummantelung vor dem Lackieren mit feinem Sandpapier gegl ttet werden um alle Unebenheiten oder scharfe Kanten zu beseitigen Tragen Sie eine Farbschicht auf Vermischen Sie das Pul...

Page 23: ...23 Fig 1A Fig 1B Fig 1C J tul S 16 C W J tul S 16 W J tul S 16 C 403 420 616 700 350 180 290 500 1200 2450 350 1000 40...

Page 24: ...2B Fig 3A Fig 3B J tul S 16 C J tul S 16 W J tul S 16 W 1 2 3 4 12 6 7 5 8 9 10 11 11 5 6 8 for Maxi J tul S 16 C 1 13 2 3 4 12 5 5 6 7 8 8 9 10 11 11 6 for Maxi 100 230 min 1000 700 1000 50 830 280 m...

Page 25: ...25 Fig 4 Fig 5 Fig 6 Fig 7 B A C...

Page 26: ...26...

Page 27: ...27...

Page 28: ...etssikringssystem basert p NS EN ISO 9001 for utvikling produksjon og salg av ildsteder V r kvalitetspolitikk skal gi kundene den trygghet og kvalitetsopplevelse som J tul har st tt for siden bedrifte...

Reviews: