7
Minimum Fireplace
Requirements
The Universal GI 350 DV gas insert has been specifi-
cally designed to be installed into a solid fuel
burning factory built fireplace or a code approved
solid fuel burning masonry fireplace with a tile flue
liner. An acceptable fireplace cavity must have the
minimum dimensions specified in fig. 3.
Do not modify or alter the construction of the
gas insert or any of its components to enable it to fit
into a fireplace. Any modification of the insert will
void the warranty, certifications and approvals of the
unit and could be dangerous.
Figure 2. Universal GI 350 DV dimensions.
A:
A:
A:
A:
A: Opening Width = 31” (787 mm)
without leveling brackets = 30” (762 mm)
B:
B:
B:
B:
B: Opening Height = 20” (520 mm)
with Scan 65i 1” riser = 21” (533 mm)
with Scan 65i 2” riser = 22” (559 mm)
C:
C:
C:
C:
C: Back Wall Width = 19” (483 mm)
without levelling brackets = 18” (457 mm)
D:
D:
D:
D:
D: Back Wall Height = 19” (483 mm)
w/ Scan 65i 1” riser = 20” (508 mm)
w/ Scan 65i 2” riser = 21” (533 mm)
E:
E:
E:
E:
E: Depth = 16” (406 mm)
Figure 3. Minimum fireplace cavity dimensions.
E
C
D
A
B
9 3/8
238 mm
5 5/8
143 mm
15
381 mm
18 3/4
575mm
2 1/2
64 mm
Height
Adj.
17 1/2
444 mm
5
127 mm
3
76 mm
4 1/4
108 mm
30 1/2
775 mm
19
483 mm
29
737 mm
22
559 mm
13 1/2
343 mm
19 1/2
495 mm
16
406 mm
Glass Frame
Latches
18 3/8
466 mm
Summary of Contents for GI 350 DV