Jøtul GI 350 DV Installation And Operation Instructions Manual Download Page 10

10

Masonry Fireplace Vent Installation

1.

1.

1.

1.

1.  Measure height of the chimney to fireplace open-

ing.  Determine if both the intake and exhaust will
be extended to the top of the chimney.

2.

2.

2.

2.

2.      Use tin snips to cut the appropriate lengths of flex

for both the intake and exhaust.

3.

3.

3.

3.

3.  Attach the appropriate ends of the flex to the

chimney termination kit.

4

4

4

4

4.....  Drop the liners down the chimney from the top

and rest the termination kit atop the chimney.

5

55

55.....  Seal the chimney termination kit to the top of the

chimney flue with high temperature sealant.

6.

6.

6.

6.

6.  Secure the appropriate DIRECT VENT CAP to the

termination kit.

77777.....  Inside the fireplace, fully extend the flex liner pipe

and cut off the excess so that the liners hang
approximately 15” from the floor of the fireplace.

8.

8.

8.

8.

8. 

 If the Air Intake pipe 

will not

     be attached to the

chimney termination kit: (See IMPORTANT NOTICE on
this below.)

a.

a.

a.

a.

a. It will be necessary to install a minimum length
of 6 ft. flex pipe up into the flue.

b

b

b

b

b.....  A metal damper block off plate must be con-
structed and installed in the fireplace damper area
to completely seal off the flue from the room.  Cut
holes in the plate for both the intake and exhaust
flex pipes.

ccccc.....      A direct vent cap is required to bring fresh air
into the chimney flue and Air Intake flex pipe.
d.

d.

d.

d.

d.  Attach the Fireplace Conversion Notice to the
back of the fireplace if appropriate.

Masonry Fireplaces

A solid-fuel fireplace chimney must be clean and in
good working order. It must be constructed of no-
combustible materials. Chimney clean-outs must fit
properly.

When installing the Universal GI 350 DV gas

insert into a masonry fireplace, the insert will be
vented through dual 3” flexible gas aluminum liners.

This co-linear installation includes a pair of 3”

flex ducts that run from the insert completely
through the existing chimney to the termination cap.

One liner is attached to the Exhaust Outlet on

the back of the unit and will carry the exhaust gases
to the outside of the house.  This exhaust liner must
be directly connected to the unit and run the full
length of the chimney.  See fig. 6.

The other 3” liner will be attached to the Air

Intake Collar on the back of the unit to provide fresh
air for combustion.  The Intake Collar is labeled for
easy identification. The liner must extend a mini-

 mini-

 mini-

 mini-

 mini-

mum o

mum o

mum o

mum o

mum of 6’

f 6’

f 6’

f 6’

f 6’ off the back of the unit and extend

through the damper area of the fireplace into the tile
liner of the chimney. This liner can also extend the
full length of the chimney and connect to the
termination cap.

IMPORTANT

If the intake flex does not extend the full length

of the chimney, forming a direct connection between
the unit and the termination cap,  A METAL BLOCK
OFF PLATE MUST BE INSTALLED to seal the air intake
from room air. Normally this sealing plate will be
installed within the existing fireplace damper area.
See fig. 6. The sealing plate is not necessary if a direct
connection is made between the cap and the fire-
place. W

W

W

W

WAR

AR

AR

AR

ARN

N

N

N

NIIIIING!

NG!

NG!

NG!

NG! Avoid cross venting the insert.

Before installation, label both ends of the exhaust flex
pipe to ensure connection to the appropriate collars on
the fireplace unit and vent termination cap.

Cutting of any sheet metal parts on a solid-fuel

fireplace is prohibited.

C

C

C

C

CANAD

ANAD

ANAD

ANAD

ANADA R

A R

A R

A R

A REQU

EQU

EQU

EQU

EQUIIIIIR

R

R

R

REMEN

EMEN

EMEN

EMEN

EMENT

TT

T

T::::: Both 

 Both 

 Both 

 Both 

 Both the In

the In

the In

the In

the Intak

tak

tak

tak

take

ee

e

e

and 

and 

and 

and 

and the E

the E

the E

the E

the Exhaust

xhaust

xhaust

xhaust

xhaust liners must

 liners must

 liners must

 liners must

 liners must e

 e

 e

 e

 extend 

xtend 

xtend 

xtend 

xtend the

the

the

the

the

full length o

full length o

full length o

full length o

full length of 

f the chimne

the chimne

the chimne

the chimne

the chimney and be secur

y and be secur

y and be secur

y and be secur

y and be securely

ely

ely

ely

ely

ccccconnec

onnec

onnec

onnec

onnected 

ted 

ted 

ted 

ted ttttto both 

o both 

o both 

o both 

o both the unit

the unit

the unit

the unit

the unit and 

 and 

 and 

 and 

 and the 

the 

the 

the 

the termi-

termi-

termi-

termi-

termi-

na

na

na

na

nation kit

tion kit

tion kit

tion kit

tion kit.....

If 

If 

If 

If 

If the fir

the fir

the fir

the fir

the fireplac

eplac

eplac

eplac

eplace has been modified 

e has been modified 

e has been modified 

e has been modified 

e has been modified ttttto

o

o

o

o

ac

ac

ac

ac

accccccommoda

ommoda

ommoda

ommoda

ommodate installa

te installa

te installa

te installa

te installation,

tion,

tion,

tion,

tion,     use anchors or

masonry nails to attach the metal Fireplace
Conversion Notice Plate supplied with this
unit to the back wall of the masonry fireplace
firebox where it will be readily seen should
the insert be removed.

IMPORTANT NOTICE:

THE USE OF AN EXISTING CHIMNEY AS AN AIR
INTAKE IS NOT COVERED UNDER THE ANSI Z21.88-
1999-CSA 2.33-M99 TEST METHODS AND RESULT-
ING ITS/WHI PRODUCT CERTIFICATION.  THE CODE
AUTHORITY HAVING JURISDICTION MUST BE
CONSULTED PRIOR TO PROCEEDING WITH THIS
INSTALLATION METHOD.

Smoke shelves, shields, and baffles may be

removed if attached with mechanical fasteners.

Summary of Contents for GI 350 DV

Page 1: ...rom a neighbor s phone Follow the gas supplier s instruction If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service...

Page 2: ...driver Flat head screwdriver 1 4 nut driver Gloves Safety glasses TorxT 20 screwdriver PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS APPLIA...

Page 3: ...d P ted P ted P ted P ted Par ar ar ar art t t t t Br Br Br Br Break eak eak eak eakdo do do do down wn wn wn wn 26 R R R R Replac eplac eplac eplac eplacemen emen emen emen ement t t t t P P P P Par...

Page 4: ...Cast Iron Double Doors 156416 Reversible Brick Panel Kit Corduroy Blk Gry 156417 Reversible Brick Panel Kit Antique Border 156418 Fuel Conversion Kit NG to LP 156444 Fuel Conversion Kit LP to NG 15644...

Page 5: ...YTHE CONSTRUCTION OFTHIS APPLIANCE OR ITS COMPONENTS ANYMODIFICATION OR ALTER ATIONWILL VOIDTHEWARRANTY CERTIFICA TION AND LISTING OFTHIS APPLIANCE In the absence of local codes the installation requi...

Page 6: ...t into a chimney that is damaged Any repairs must be made prior to install ing the insert If you are unsure of the condition of your fireplace and chimney contact a professional fireplace technician o...

Page 7: ...ls of the unit and could be dangerous Figure 2 Universal GI 350 DV dimensions A A A A A Opening Width 31 787 mm without leveling brackets 30 762 mm B B B B B Opening Height 20 520 mm with Scan 65i 1 r...

Page 8: ...ible material It must extend 16 forward of the firebox glass panel and extend 18 to either side of the fireplace centerline See fig 4 Fireplace Facing Options J tul Cast Iron Surround 34 1 2 x 24 1 2...

Page 9: ...nents not manufactured or approved by J tul or failure to meet all clearance requirements will void all warranties and could result in property damage bodily injury or serious fire Never modify any ve...

Page 10: ...liner of the chimney This liner can also extend the full length of the chimney and connect to the termination cap IMPORTANT If the intake flex does not extend the full length of the chimney forming a...

Page 11: ...cut or pried off 2 Remove the damper assembly This includes the damper blade handle and any linkage Two 3 liners must be able to pass through the damper area 3 Remove any fire screen or door assembly...

Page 12: ...te installa te installa te installa te installation tion tion tion tion use anchors or masonry nails to attach the metal Fireplace Conversion Notice Plate supplied with this unit to the back wall of...

Page 13: ...ers in the block off plate C C C C C A direct vent cap is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D D D D D Attach the Fireplace Conversi...

Page 14: ...n gas supply and test for gas leaks using a 50 50 soapy water solution or a gas detector Never use an open flame to check for leaks A T HANDLE GAS SHUT OFF VALVE IS REQUIRED IN MASSACHUSETTS IN COMPLI...

Page 15: ...0WC 1 74 kPa Propane 12 0WC 2 98 kPa 13 0WC 3 23 kPa Manif Manif Manif Manif Manifold Pr old Pr old Pr old Pr old Pressur essur essur essur essure e e e e MIN MAX Natural Gas 1 2WC 0 29 kPa 3 8WC 95...

Page 16: ...e indicator LP or NG is oriented facing you See fig 15 4 4 4 4 4 Chang Chang Chang Chang Change e e e e the P the P the P the P the Pilot ilot ilot ilot ilot Orific Orific Orific Orific Orifice e e e...

Page 17: ...net floor so that it may be seen by anyone servicing the fireplace Apply LABEL B to the Rating Plate in the space provided 9 9 9 9 9 R R R R Reassemble eassemble eassemble eassemble eassemble the fir...

Page 18: ...witch 1 Remove the switch box from the valve compart ment Remove the switch coverplate and discon nect the wires from the TH and TH TP terminals under the valve 2 Install the Receiver switch battery b...

Page 19: ...ve not e not e not e not e not alr alr alr alr already done so eady done so eady done so eady done so eady done so See fig 1 pg 3 2 2 2 2 2 R R R R Remo emo emo emo emov v v v ve e e e e the L the L...

Page 20: ...hown in fig 26 4 4 4 4 4 Set the Right Log on the appropriate pegs as shown in fig 27 5 5 5 5 5 Lightly scatter the Ember Stones included in the Log Set package over the burner plate Place them direct...

Page 21: ...PI PI PI PI PIL L L L LO O O O OT FL T FL T FL T FL T FLA A A A AME ME ME ME ME The pilot flame should be steady not lifting or floating The flame should be blue in color around the pilot hood with tr...

Page 22: ...t the factory No further assembly is required All assemblies utilize hooked brackets fig 30 that simply hang onto the inboard tabs on the fireplace cabinet as shown in fig 10 on page 14 Be certain the...

Page 23: ...n it is com mon to detect some odor as the metal and manu facturing materials cure under heat This condition is temporary and can be alleviated by allowing plenty of fresh air to circulate through the...

Page 24: ...l Care The black coating around the perimeter of the back of this glass is especially prone to fingerprinting when handled Fingerprints may be wiped clean with a soft cloth and any common window clean...

Page 25: ...blanket or towel 3 The glass panel is held in place by four retainer clips Use a screwdriver to carefully pry these up off the edge of the glass retaining walls See fig 35 4 Remove the old gasket mate...

Page 26: ...16 58 59 61 60 62 63 64 80 83 81 82 37 38 39 40 41 42 55 1 2 3 4 6 5 7 8 22 23 24 25 44 45 43 46 47 48 49 26 27 28 29 30 9 10 11 13 12 52 53 54 77 65 66 67 68 69 70 71 72 73 74 78 79 75 76 Figure 37 P...

Page 27: ...8 Pilot Access Panel 221399 49 Gasket Pilot Access Panel 129153 50 Screw 8 x 1 2 Blk 117917 51 Cabinet Wall Right 221743 52 Snapstat 120 110 F 220617 53 Screw 8 x 1 2 Blk 117917 54 Snapstat Bracket 22...

Page 28: ...the insert Burner switch box using the two sheet metal screws previously removed from the original coverplate See fig 39 4 Attach the Receiver Coverplate to the Receiver using the two small screws sup...

Page 29: ...29...

Page 30: ..._____ NA NA NA NA NAME OF I ME OF I ME OF I ME OF I ME OF INS NS NS NS NST T T T TALLER ______________________ ALLER ______________________ ALLER ______________________ ALLER ______________________ AL...

Page 31: ...o the floor because some gas is heavier than air and will settle to the floor W W W W WHA HA HA HA HAT T T T T T T T T TO DO I O DO I O DO I O DO I O DO IF F F F F Y Y Y Y YOU S OU S OU S OU S OU SMEL...

Page 32: ...installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification co...

Reviews: