10
Masonry Fireplace Vent Installation
1.
1.
1.
1.
1. Measure height of the chimney to fireplace open-
ing. Determine if both the intake and exhaust will
be extended to the top of the chimney.
2.
2.
2.
2.
2. Use tin snips to cut the appropriate lengths of flex
for both the intake and exhaust.
3.
3.
3.
3.
3. Attach the appropriate ends of the flex to the
chimney termination kit.
4
4
4
4
4..... Drop the liners down the chimney from the top
and rest the termination kit atop the chimney.
5
55
55..... Seal the chimney termination kit to the top of the
chimney flue with high temperature sealant.
6.
6.
6.
6.
6. Secure the appropriate DIRECT VENT CAP to the
termination kit.
77777..... Inside the fireplace, fully extend the flex liner pipe
and cut off the excess so that the liners hang
approximately 15” from the floor of the fireplace.
8.
8.
8.
8.
8.
If the Air Intake pipe
will not
be attached to the
chimney termination kit: (See IMPORTANT NOTICE on
this below.)
a.
a.
a.
a.
a. It will be necessary to install a minimum length
of 6 ft. flex pipe up into the flue.
b
b
b
b
b..... A metal damper block off plate must be con-
structed and installed in the fireplace damper area
to completely seal off the flue from the room. Cut
holes in the plate for both the intake and exhaust
flex pipes.
ccccc..... A direct vent cap is required to bring fresh air
into the chimney flue and Air Intake flex pipe.
d.
d.
d.
d.
d. Attach the Fireplace Conversion Notice to the
back of the fireplace if appropriate.
Masonry Fireplaces
A solid-fuel fireplace chimney must be clean and in
good working order. It must be constructed of no-
combustible materials. Chimney clean-outs must fit
properly.
When installing the Universal GI 350 DV gas
insert into a masonry fireplace, the insert will be
vented through dual 3” flexible gas aluminum liners.
This co-linear installation includes a pair of 3”
flex ducts that run from the insert completely
through the existing chimney to the termination cap.
One liner is attached to the Exhaust Outlet on
the back of the unit and will carry the exhaust gases
to the outside of the house. This exhaust liner must
be directly connected to the unit and run the full
length of the chimney. See fig. 6.
The other 3” liner will be attached to the Air
Intake Collar on the back of the unit to provide fresh
air for combustion. The Intake Collar is labeled for
easy identification. The liner must extend a mini-
mini-
mini-
mini-
mini-
mum o
mum o
mum o
mum o
mum of 6’
f 6’
f 6’
f 6’
f 6’ off the back of the unit and extend
through the damper area of the fireplace into the tile
liner of the chimney. This liner can also extend the
full length of the chimney and connect to the
termination cap.
IMPORTANT
If the intake flex does not extend the full length
of the chimney, forming a direct connection between
the unit and the termination cap, A METAL BLOCK
OFF PLATE MUST BE INSTALLED to seal the air intake
from room air. Normally this sealing plate will be
installed within the existing fireplace damper area.
See fig. 6. The sealing plate is not necessary if a direct
connection is made between the cap and the fire-
place. W
W
W
W
WAR
AR
AR
AR
ARN
N
N
N
NIIIIING!
NG!
NG!
NG!
NG! Avoid cross venting the insert.
Before installation, label both ends of the exhaust flex
pipe to ensure connection to the appropriate collars on
the fireplace unit and vent termination cap.
Cutting of any sheet metal parts on a solid-fuel
fireplace is prohibited.
C
C
C
C
CANAD
ANAD
ANAD
ANAD
ANADA R
A R
A R
A R
A REQU
EQU
EQU
EQU
EQUIIIIIR
R
R
R
REMEN
EMEN
EMEN
EMEN
EMENT
TT
T
T::::: Both
Both
Both
Both
Both the In
the In
the In
the In
the Intak
tak
tak
tak
take
ee
e
e
and
and
and
and
and the E
the E
the E
the E
the Exhaust
xhaust
xhaust
xhaust
xhaust liners must
liners must
liners must
liners must
liners must e
e
e
e
extend
xtend
xtend
xtend
xtend the
the
the
the
the
full length o
full length o
full length o
full length o
full length of
f
f
f
f the chimne
the chimne
the chimne
the chimne
the chimney and be secur
y and be secur
y and be secur
y and be secur
y and be securely
ely
ely
ely
ely
ccccconnec
onnec
onnec
onnec
onnected
ted
ted
ted
ted ttttto both
o both
o both
o both
o both the unit
the unit
the unit
the unit
the unit and
and
and
and
and the
the
the
the
the termi-
termi-
termi-
termi-
termi-
na
na
na
na
nation kit
tion kit
tion kit
tion kit
tion kit.....
If
If
If
If
If the fir
the fir
the fir
the fir
the fireplac
eplac
eplac
eplac
eplace has been modified
e has been modified
e has been modified
e has been modified
e has been modified ttttto
o
o
o
o
ac
ac
ac
ac
accccccommoda
ommoda
ommoda
ommoda
ommodate installa
te installa
te installa
te installa
te installation,
tion,
tion,
tion,
tion, use anchors or
masonry nails to attach the metal Fireplace
Conversion Notice Plate supplied with this
unit to the back wall of the masonry fireplace
firebox where it will be readily seen should
the insert be removed.
IMPORTANT NOTICE:
THE USE OF AN EXISTING CHIMNEY AS AN AIR
INTAKE IS NOT COVERED UNDER THE ANSI Z21.88-
1999-CSA 2.33-M99 TEST METHODS AND RESULT-
ING ITS/WHI PRODUCT CERTIFICATION. THE CODE
AUTHORITY HAVING JURISDICTION MUST BE
CONSULTED PRIOR TO PROCEEDING WITH THIS
INSTALLATION METHOD.
Smoke shelves, shields, and baffles may be
removed if attached with mechanical fasteners.
Summary of Contents for GI 350 DV
Page 29: ...29...