Jøtul GI 350 DV Installation And Operation Instructions Manual Download Page 27

27

No.

Description

Part Number

Universal GI 

350

 DV Part List

No.

Description

Part Number

1.

Screw, Pan Head 10-32 x 3/8

117911

2.

Valve Bracket

221385

3.

Screw, #8 x 1/2” Blk

117917

4.

Piezo Ignitor Button

3902573

5.

Ignitor Bracket

3902576

6.

Screw, Pan Hd M4 x 8

117920

7.

Valve, NG, High Temp, 50% TD

222263

8.

Elbow, 90° Brass  3/8 NTP

222292

9.

Screw, #8 x 1/2” Blk

117917

10.

Cabinet Wall, Rear

221745

11.

Blower Mounting  Bracket

221738

12.

Screw, #8 x 1/2” Blk

117917

13.

Blower, TransFlow  120 CFM

222072

14.

Heat Shield, Left

222091

15.

Cabinet Wall, Left

221744

16.

Screw, #8 x 1/2” Blk

117917

17.

Control Box Receptacle

222048

18.

Wingnut, M6 Zinc

117975

19.

Switch, On/Off/T’stat, Plain

220703

20.

Burner Switch Cover Plate, Silkscreened

222272

21.

Screw, #8 x 1/2” Blk

117917

22.

Tinnerman U-Clip

220042

23.

Glass Gasket, .250 x 1” Tadpole Fiberglass

129124

24.

Glass, Ceramic / 5 mm

221718

25.

Glass Frame

22171092

26.

Nut, M6 Hex Plain

9930

27.

Screw, #10 x 3/4” Sheet Metal

118043

28.

Leg Leveler Bracket

222440

29.

Cabinet Base

221709

30.

Latch Assembly

221712

31.

Firebox Weldment

221700

32.

Gasket, Delayed Ignition Relief Door

129678

33.

Relief Door

222432

34.

Screw, #8 x 1/2” Blk

117917

35.

Heat Shield, Firebox Top

222416

36.

Gasket,  3” Adaptor

129677

37.

Vent Connector Assembly

222259

38.

Gasket, Vent Connector

222281

39.

Cabinet Wall, Top

221746

40.

Air Deflector, Top Cabinet

222457

41.

Vent Pipe Adaptor

222205

42.

Vent Installation Tool

222267

43.

Screw,  #8 x 3/4”

117986

44.

Pilot Assembly

129471

45.

Pilot Spacer

222284

46.

Gasket, Pilot Assembly

129670

47.

Screw, #8 x 1/2” Blk

117917

48.

Pilot Access Panel

221399

49.

Gasket, Pilot Access Panel

129153

50.

Screw, #8 x 1/2” Blk

117917

51.

Cabinet Wall, Right

221743

52.

Snapstat, 120-110°F

220617

53.

Screw, #8 x 1/2” Blk

117917

54.

Snapstat Bracket

220989

55.

Heat Shield, Right

222092

56.

Screw, #8 x 1/2” Blk

117917

57.

Glass Frame Latch Release Tool

222268

58.

Wire Strain Relief, Heyco

117951

59.

Control Box Receptacle

222048

60.

Switch, On/Of/T’stat Plain

220703

61.

Rheostat, Long Lead 26”

220970

62.

Cover Plate, Blower Switch Box

221394

63.

Screw, #8 x 1/2” Blk

117917

64.

Rheostat Control Knob

220709

65.

Fettle, Matte Black

10434792

Fettle, Blue Black Enamel

10434727

66.

Top Plate, Burner

222254

67.

Air Deflector, Burner

222294

68.

Nut, Hex, Plain M6 DIN 934

9930

69.

Gasket, Burner

222206

70.

Screw, #8 x 1/2” Blk

117917

71.

Burner Base

104253

72.

Venturi Tube

221391

73.

Tube Holder

103992

74.

Nut, Serrated Flange Plain

117968

66 -74. Burner Assembly, Replacement

156453

75.

Primary Air Shutter Assembly

221390

76.

Handle, Primary Air

221979

77.

Gasket, 2.25 in. OD. x .125 in.

220734

78.

Fender Washer,  .250 in. x 2.250 in.

118023

79.

Wingnut, M6 Zinc

117975

80.

Screw, #8 x 1/2” Blk

117917

81.

Orifice, #38 NG

129130

82.

Gasket, Drop-in Orifice Holder

222280

83.

Orifice Holder, Drop-in Assembly

222291

84.

Screw, #8 x 1/2” Blk

117917

85.

Wall, Inner Back

221704

86.

Screw, #8 x 1/2” Blk

117917

87.

Burner Skirt, Rear

22199892

88.

Log Set, (4 pcs.)  Illustrated on pg. 20.

156409

89.

Blower Kit*

156455

90.

Rheostat Kit*

156456

91.

Glass Kit - inc. gasket & clips

156457

92.

Blower Switch Box Kit, complete

156459

93.

Vent Adaptor Assembly , inc. gaskets

156464

* not illustrated

Use only genuine Jøtul Replacement Parts available
from your local Authorized Jøtul Dealer or by
contacting:

Jøtul North America
55 Hutcherson Dr.
Gorham, ME  04038

207 591-6601

Summary of Contents for GI 350 DV

Page 1: ...rom a neighbor s phone Follow the gas supplier s instruction If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service...

Page 2: ...driver Flat head screwdriver 1 4 nut driver Gloves Safety glasses TorxT 20 screwdriver PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS APPLIA...

Page 3: ...d P ted P ted P ted P ted Par ar ar ar art t t t t Br Br Br Br Break eak eak eak eakdo do do do down wn wn wn wn 26 R R R R Replac eplac eplac eplac eplacemen emen emen emen ement t t t t P P P P Par...

Page 4: ...Cast Iron Double Doors 156416 Reversible Brick Panel Kit Corduroy Blk Gry 156417 Reversible Brick Panel Kit Antique Border 156418 Fuel Conversion Kit NG to LP 156444 Fuel Conversion Kit LP to NG 15644...

Page 5: ...YTHE CONSTRUCTION OFTHIS APPLIANCE OR ITS COMPONENTS ANYMODIFICATION OR ALTER ATIONWILL VOIDTHEWARRANTY CERTIFICA TION AND LISTING OFTHIS APPLIANCE In the absence of local codes the installation requi...

Page 6: ...t into a chimney that is damaged Any repairs must be made prior to install ing the insert If you are unsure of the condition of your fireplace and chimney contact a professional fireplace technician o...

Page 7: ...ls of the unit and could be dangerous Figure 2 Universal GI 350 DV dimensions A A A A A Opening Width 31 787 mm without leveling brackets 30 762 mm B B B B B Opening Height 20 520 mm with Scan 65i 1 r...

Page 8: ...ible material It must extend 16 forward of the firebox glass panel and extend 18 to either side of the fireplace centerline See fig 4 Fireplace Facing Options J tul Cast Iron Surround 34 1 2 x 24 1 2...

Page 9: ...nents not manufactured or approved by J tul or failure to meet all clearance requirements will void all warranties and could result in property damage bodily injury or serious fire Never modify any ve...

Page 10: ...liner of the chimney This liner can also extend the full length of the chimney and connect to the termination cap IMPORTANT If the intake flex does not extend the full length of the chimney forming a...

Page 11: ...cut or pried off 2 Remove the damper assembly This includes the damper blade handle and any linkage Two 3 liners must be able to pass through the damper area 3 Remove any fire screen or door assembly...

Page 12: ...te installa te installa te installa te installation tion tion tion tion use anchors or masonry nails to attach the metal Fireplace Conversion Notice Plate supplied with this unit to the back wall of...

Page 13: ...ers in the block off plate C C C C C A direct vent cap is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D D D D D Attach the Fireplace Conversi...

Page 14: ...n gas supply and test for gas leaks using a 50 50 soapy water solution or a gas detector Never use an open flame to check for leaks A T HANDLE GAS SHUT OFF VALVE IS REQUIRED IN MASSACHUSETTS IN COMPLI...

Page 15: ...0WC 1 74 kPa Propane 12 0WC 2 98 kPa 13 0WC 3 23 kPa Manif Manif Manif Manif Manifold Pr old Pr old Pr old Pr old Pressur essur essur essur essure e e e e MIN MAX Natural Gas 1 2WC 0 29 kPa 3 8WC 95...

Page 16: ...e indicator LP or NG is oriented facing you See fig 15 4 4 4 4 4 Chang Chang Chang Chang Change e e e e the P the P the P the P the Pilot ilot ilot ilot ilot Orific Orific Orific Orific Orifice e e e...

Page 17: ...net floor so that it may be seen by anyone servicing the fireplace Apply LABEL B to the Rating Plate in the space provided 9 9 9 9 9 R R R R Reassemble eassemble eassemble eassemble eassemble the fir...

Page 18: ...witch 1 Remove the switch box from the valve compart ment Remove the switch coverplate and discon nect the wires from the TH and TH TP terminals under the valve 2 Install the Receiver switch battery b...

Page 19: ...ve not e not e not e not e not alr alr alr alr already done so eady done so eady done so eady done so eady done so See fig 1 pg 3 2 2 2 2 2 R R R R Remo emo emo emo emov v v v ve e e e e the L the L...

Page 20: ...hown in fig 26 4 4 4 4 4 Set the Right Log on the appropriate pegs as shown in fig 27 5 5 5 5 5 Lightly scatter the Ember Stones included in the Log Set package over the burner plate Place them direct...

Page 21: ...PI PI PI PI PIL L L L LO O O O OT FL T FL T FL T FL T FLA A A A AME ME ME ME ME The pilot flame should be steady not lifting or floating The flame should be blue in color around the pilot hood with tr...

Page 22: ...t the factory No further assembly is required All assemblies utilize hooked brackets fig 30 that simply hang onto the inboard tabs on the fireplace cabinet as shown in fig 10 on page 14 Be certain the...

Page 23: ...n it is com mon to detect some odor as the metal and manu facturing materials cure under heat This condition is temporary and can be alleviated by allowing plenty of fresh air to circulate through the...

Page 24: ...l Care The black coating around the perimeter of the back of this glass is especially prone to fingerprinting when handled Fingerprints may be wiped clean with a soft cloth and any common window clean...

Page 25: ...blanket or towel 3 The glass panel is held in place by four retainer clips Use a screwdriver to carefully pry these up off the edge of the glass retaining walls See fig 35 4 Remove the old gasket mate...

Page 26: ...16 58 59 61 60 62 63 64 80 83 81 82 37 38 39 40 41 42 55 1 2 3 4 6 5 7 8 22 23 24 25 44 45 43 46 47 48 49 26 27 28 29 30 9 10 11 13 12 52 53 54 77 65 66 67 68 69 70 71 72 73 74 78 79 75 76 Figure 37 P...

Page 27: ...8 Pilot Access Panel 221399 49 Gasket Pilot Access Panel 129153 50 Screw 8 x 1 2 Blk 117917 51 Cabinet Wall Right 221743 52 Snapstat 120 110 F 220617 53 Screw 8 x 1 2 Blk 117917 54 Snapstat Bracket 22...

Page 28: ...the insert Burner switch box using the two sheet metal screws previously removed from the original coverplate See fig 39 4 Attach the Receiver Coverplate to the Receiver using the two small screws sup...

Page 29: ...29...

Page 30: ..._____ NA NA NA NA NAME OF I ME OF I ME OF I ME OF I ME OF INS NS NS NS NST T T T TALLER ______________________ ALLER ______________________ ALLER ______________________ ALLER ______________________ AL...

Page 31: ...o the floor because some gas is heavier than air and will settle to the floor W W W W WHA HA HA HA HAT T T T T T T T T TO DO I O DO I O DO I O DO I O DO IF F F F F Y Y Y Y YOU S OU S OU S OU S OU SMEL...

Page 32: ...installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification co...

Reviews: