Safety Information

„

Due to the high operating temperatures this
appliance should be located out of traffic and
away from furniture, draperies, etc. Maintain
proper clearance to combustible mantels and
fireplace trim.

„

Children and adults should be alerted to the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.

„

Young children should be supervised while they
are in the same room as the fireplace.

„

Clothing or other flammable materials should not
be placed on or near the fireplace.

Surveiller les enfants.  Garder les vêtements, les
meubles, l’essence ou autres liquides à vapeur
inflammables lin de l’appareil.

„

Never allow anyone to use the fireplace if they are
unfamiliar with its operation.

„

NEVER store or use gasoline or any other flam-
mable vapors or liquids in the vicinity of the
fireplace.

„

Never burn any solid materials (wood, cardboard,
paper, coal, etc.) in this gas fireplace. Use with
natural gas or propane fuel ONLY.

„

Any safety screen, glass or guard removed for
servicing the appliance must be replaced prior to
operating the appliance.

„

„

„

„

„

Do not slam or strike the glass panel.

„

„

„

„

„

This appliance is NOT for use with aftermarket
glass doors. This appliance is approved for use
only with the door facings, surround panels and
glass panel options listed on page 4 of this
manual.
Cet appareil ne sert pas avec des portes en verre
de marché des accessoires. Cet appareil est
approuvé pour l’usage seulement avec les
revêtements de porte, entoure les options de
panneau et en verre de panneau énumérées à la
page 4 de ce manuel.

„

„

„

„

„

Wear gloves and safety glasses while performing
maintenance procedures.

Electrical Hazards

„

„

„

„

„

Be aware of electrical wiring locations when
cutting holes in walls and ceilings for termination.

„

„

„

„

„

The Jøtul GI 350 DV Blower must be electrically
grounded in accordance with local codes or, in the

Installation Requirements

The Universal GI 350 DV Gas Insert can be installed in
most solid fuel burning fireplaces of either masonry
construction or a prefabricated factory built fireplace.

Prior to any installation, the existing chimney

exhaust flue must be thoroughly cleaned and
completely inspected by a qualified chimney sweep
or fireplace service person.

Do not install this insert into a chimney that is

damaged. Any repairs must be made prior to install-
ing the insert.  If you are unsure of the condition of
your fireplace and chimney, contact a  professional
fireplace technician or your local authorized Jøtul
dealer for professional assistance.

DO NO

DO NO

DO NO

DO NO

DO NOT R

T R

T R

T R

T REM

EM

EM

EM

EMO

O

O

O

OVE B

VE B

VE B

VE B

VE BR

R

R

R

RIC

IC

IC

IC

ICK

K

K

K

KS OR M

S OR M

S OR M

S OR M

S OR MOR

OR

OR

OR

ORT

TT

T

TAR FR

AR FR

AR FR

AR FR

AR FRO

O

O

O

OM

M

M

M

M

T

TT

T

TH

H

H

H

HE FI

E FI

E FI

E FI

E FIR

R

R

R

REPL

EPL

EPL

EPL

EPLA

A

A

A

AC

C

C

C

CE OR C

E OR C

E OR C

E OR C

E OR CH

H

H

H

HIMN

IMN

IMN

IMN

IMNE

EE

EEY S

Y S

Y S

Y S

Y ST

TT

T

TRUC

RUC

RUC

RUC

RUCT

TT

T

TU

U

U

U

UR

R

R

R

RE.

E.

E.

E.

E.      However,

masonry or steel may be removed from the smoke
shelf and adjacent damper frame area to accommo-
date installation of a chimney liner, provided that
their removal will not weaken the structure of the
fireplace or chimney, and will not reduce protection
for combustible materials.

If 

If 

If 

If 

If the fir

the fir

the fir

the fir

the fireplac

eplac

eplac

eplac

eplace has been modified 

e has been modified 

e has been modified 

e has been modified 

e has been modified ttttto ac

o ac

o ac

o ac

o accccccom-

om-

om-

om-

om-

moda

moda

moda

moda

modate installa

te installa

te installa

te installa

te installation,

tion,

tion,

tion,

tion,     use anchors or masonry nails to

attach the metal Fireplace Conversion Notice Plate to
the back wall of the masonry fireplace firebox where
it will be readily seen should the insert be removed.

THIS APPLIANCE MUST NOT BE CONNECTED TO A

CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE
OF ANY KIND.

All venting components must be installed in

accordance with the terms of their listing and
manufacturer’s instructions.  Refer to the pipe
manufacturer’s instructions for proper pipe clear-
ances.

This fireplace insert is specifically designed for

use with 3” Type B vent pipe components or a Listed
Flexible gas liner.

absence of local codes, with the current ANSI/
NFPA 70, National Electrical Code or CSA C22.1-
Canadian Electrical Code.

„

„

„

„

„

The GI 350 DV Blower is supplied with a three-
prong (grounding) plug for protection against
shock hazard and should be plugged directly into a
properly grounded three-prong receptacle.  DO
NOT CUT OR REMOVE THE GROUNDING PRONG
FROM THE PLUG.

„

„

„

„

„

Always disconnect the power supply when per-
forming routine service on the fireplace.

Summary of Contents for GI 350 DV

Page 1: ...rom a neighbor s phone Follow the gas supplier s instruction If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service...

Page 2: ...driver Flat head screwdriver 1 4 nut driver Gloves Safety glasses TorxT 20 screwdriver PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS APPLIA...

Page 3: ...d P ted P ted P ted P ted Par ar ar ar art t t t t Br Br Br Br Break eak eak eak eakdo do do do down wn wn wn wn 26 R R R R Replac eplac eplac eplac eplacemen emen emen emen ement t t t t P P P P Par...

Page 4: ...Cast Iron Double Doors 156416 Reversible Brick Panel Kit Corduroy Blk Gry 156417 Reversible Brick Panel Kit Antique Border 156418 Fuel Conversion Kit NG to LP 156444 Fuel Conversion Kit LP to NG 15644...

Page 5: ...YTHE CONSTRUCTION OFTHIS APPLIANCE OR ITS COMPONENTS ANYMODIFICATION OR ALTER ATIONWILL VOIDTHEWARRANTY CERTIFICA TION AND LISTING OFTHIS APPLIANCE In the absence of local codes the installation requi...

Page 6: ...t into a chimney that is damaged Any repairs must be made prior to install ing the insert If you are unsure of the condition of your fireplace and chimney contact a professional fireplace technician o...

Page 7: ...ls of the unit and could be dangerous Figure 2 Universal GI 350 DV dimensions A A A A A Opening Width 31 787 mm without leveling brackets 30 762 mm B B B B B Opening Height 20 520 mm with Scan 65i 1 r...

Page 8: ...ible material It must extend 16 forward of the firebox glass panel and extend 18 to either side of the fireplace centerline See fig 4 Fireplace Facing Options J tul Cast Iron Surround 34 1 2 x 24 1 2...

Page 9: ...nents not manufactured or approved by J tul or failure to meet all clearance requirements will void all warranties and could result in property damage bodily injury or serious fire Never modify any ve...

Page 10: ...liner of the chimney This liner can also extend the full length of the chimney and connect to the termination cap IMPORTANT If the intake flex does not extend the full length of the chimney forming a...

Page 11: ...cut or pried off 2 Remove the damper assembly This includes the damper blade handle and any linkage Two 3 liners must be able to pass through the damper area 3 Remove any fire screen or door assembly...

Page 12: ...te installa te installa te installa te installation tion tion tion tion use anchors or masonry nails to attach the metal Fireplace Conversion Notice Plate supplied with this unit to the back wall of...

Page 13: ...ers in the block off plate C C C C C A direct vent cap is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D D D D D Attach the Fireplace Conversi...

Page 14: ...n gas supply and test for gas leaks using a 50 50 soapy water solution or a gas detector Never use an open flame to check for leaks A T HANDLE GAS SHUT OFF VALVE IS REQUIRED IN MASSACHUSETTS IN COMPLI...

Page 15: ...0WC 1 74 kPa Propane 12 0WC 2 98 kPa 13 0WC 3 23 kPa Manif Manif Manif Manif Manifold Pr old Pr old Pr old Pr old Pressur essur essur essur essure e e e e MIN MAX Natural Gas 1 2WC 0 29 kPa 3 8WC 95...

Page 16: ...e indicator LP or NG is oriented facing you See fig 15 4 4 4 4 4 Chang Chang Chang Chang Change e e e e the P the P the P the P the Pilot ilot ilot ilot ilot Orific Orific Orific Orific Orifice e e e...

Page 17: ...net floor so that it may be seen by anyone servicing the fireplace Apply LABEL B to the Rating Plate in the space provided 9 9 9 9 9 R R R R Reassemble eassemble eassemble eassemble eassemble the fir...

Page 18: ...witch 1 Remove the switch box from the valve compart ment Remove the switch coverplate and discon nect the wires from the TH and TH TP terminals under the valve 2 Install the Receiver switch battery b...

Page 19: ...ve not e not e not e not e not alr alr alr alr already done so eady done so eady done so eady done so eady done so See fig 1 pg 3 2 2 2 2 2 R R R R Remo emo emo emo emov v v v ve e e e e the L the L...

Page 20: ...hown in fig 26 4 4 4 4 4 Set the Right Log on the appropriate pegs as shown in fig 27 5 5 5 5 5 Lightly scatter the Ember Stones included in the Log Set package over the burner plate Place them direct...

Page 21: ...PI PI PI PI PIL L L L LO O O O OT FL T FL T FL T FL T FLA A A A AME ME ME ME ME The pilot flame should be steady not lifting or floating The flame should be blue in color around the pilot hood with tr...

Page 22: ...t the factory No further assembly is required All assemblies utilize hooked brackets fig 30 that simply hang onto the inboard tabs on the fireplace cabinet as shown in fig 10 on page 14 Be certain the...

Page 23: ...n it is com mon to detect some odor as the metal and manu facturing materials cure under heat This condition is temporary and can be alleviated by allowing plenty of fresh air to circulate through the...

Page 24: ...l Care The black coating around the perimeter of the back of this glass is especially prone to fingerprinting when handled Fingerprints may be wiped clean with a soft cloth and any common window clean...

Page 25: ...blanket or towel 3 The glass panel is held in place by four retainer clips Use a screwdriver to carefully pry these up off the edge of the glass retaining walls See fig 35 4 Remove the old gasket mate...

Page 26: ...16 58 59 61 60 62 63 64 80 83 81 82 37 38 39 40 41 42 55 1 2 3 4 6 5 7 8 22 23 24 25 44 45 43 46 47 48 49 26 27 28 29 30 9 10 11 13 12 52 53 54 77 65 66 67 68 69 70 71 72 73 74 78 79 75 76 Figure 37 P...

Page 27: ...8 Pilot Access Panel 221399 49 Gasket Pilot Access Panel 129153 50 Screw 8 x 1 2 Blk 117917 51 Cabinet Wall Right 221743 52 Snapstat 120 110 F 220617 53 Screw 8 x 1 2 Blk 117917 54 Snapstat Bracket 22...

Page 28: ...the insert Burner switch box using the two sheet metal screws previously removed from the original coverplate See fig 39 4 Attach the Receiver Coverplate to the Receiver using the two small screws sup...

Page 29: ...29...

Page 30: ..._____ NA NA NA NA NAME OF I ME OF I ME OF I ME OF I ME OF INS NS NS NS NST T T T TALLER ______________________ ALLER ______________________ ALLER ______________________ ALLER ______________________ AL...

Page 31: ...o the floor because some gas is heavier than air and will settle to the floor W W W W WHA HA HA HA HAT T T T T T T T T TO DO I O DO I O DO I O DO I O DO IF F F F F Y Y Y Y YOU S OU S OU S OU S OU SMEL...

Page 32: ...installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification co...

Reviews: