11
USA/Canada
Wall Shield for close clearance
Combustible wall
Wall Shield
Must be 30” wide and centred behind the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 32” high.
With optional short legs, the shield must be 30” high.
Combustible wall
Wall Shield
The wall shield must extend
a min. of
4
” (
102
mm) past
the side of the stove.
The wall shield must extend
a min. of
4
” (
102
mm) past
the ash lip of the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 40” high.
With optional short legs, the shield must be 38” high.
Both shields must extend and join in the corner.
Combustible wall
Wall shield
The wall shield must
extend a min. of 12” (305
mm) past the side of the
stove.
The wall shield must extend
a min. of 12” (305 mm) past
the ash lip of the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 40” high.
With optional short legs, the shield must be 38” high.
Both shields must extend and join in the corner.
f i r e - p a r t s . c o m