background image

21

Jøtul C 

350

 Winterport  138376_Rev_Q   2 / 17

 No.  Description 

Part Number

1. 

Rear Shroud 

220904

2. 

Screw, #8 x 5/8”  Hex Slt 

117917

3. 

Nut, M6 Flange 

117968

Firebox Assembly 

220909

5. 

Nut, M6 Hex 

    9930

6. 

Gasket, Secondary Air Channel 

221750

7. 

Secondary Air Channel 

221721

8. 

AC  Power Receptacle 

221790

9. 

Screw, #8 x .62 Pan Head Type A SMS 

118057

10. 

Receptacle Mounting Plate 

221798

11. 

Receptacle Mounting Plate Gasket 

221799

12. 

Bolt, M6 x 12 Hex Head Flange 

117130

13. 

Blower Shield Assembly 

221959

14. 

Firebox Support 

221759 

19. 

Blower Attachment Clip 

121041

20.  Spacer, .250 x .500 

117994

21. 

Guide, Left Blower 

221764

22.  Shroud Assembly, Base 

220905

23. 

Guide, Right Blower 

221763

24.  Left Blower Assembly 

156047

25.  Nut, M4 Hex 

117922

26.  Right Blower Assembly  w/o Rheostat 

156048

27. 

Right Blower Base Assembly 

221965

28.  Rocker Switch 

220703

29.  Rheostat, Solid-state Variable / Rplcmt Kit 

156051

30.  Rheostat Control Knob 

221788

31. 

Snap-stat, 110°F - 10°F 

221113

32. 

Receptacle Cover Plate 

221967

33. 

Insulating Panel, Grate 

221784

34.  Bolt, M6 x 10 Hex Head Serr. Flange 

9962

35. 

Hang Tab 

129680

36.  Control Door, Matte Black Paint, inc. hardware 

156052

 

Control Door, Blue Black Enamel 

156070

 

Control Door, Jøtul Iron Paint 

156053

37. 

Bottom Grate Plate 

104277

38.  Screw, M6 x 8 Pan Head 

117505

39.  Glass Clip  

153620

40.  Glass Panel, Ceramic IR Coated 

221719

41. 

Rope Gasket, Fiberglass - LD .250 x 52” - Glass 

200024

42.  Rope Gasket, Fiberglass - LD .360 x 70” - Door 

100038

43.  Door Latch Bolt 

221720

45.  Cast Door Handle 

10371292

46. Washer 

117947

47. 

Insulating Washer 

124853

48.  Wooden Door Knob 

126244

49.  Door Handle Sleeve 

126229

50.  Bolt, M6 x 40 PHP 

117796

51. 

Roll Pin, 5 mm x 24 mm 

117733

52. 

Door Handle Compression Spring 

126164

53. 

Washer,  Door Handle 

117587

54.  Hinge Pin 

127075

55. 

Front Asy. Complete, inc. Door / Matte Black Paint  156054

 

Front Asy. Complete, inc.Door  /  Blue Black Enamel  156058

 

Front Asy. Complete, inc.Door / Jøtul Iron Paint 

156074

Jøtul C 

350

 Winterport Parts List

 No.  Description 

Part Number

56.  Rope Gasket, Fiberglass LD .360 x 78” - Frnt Plate 

100038

57. 

Air Slider,  Matte Black Paint 

156092

 

Air Slider,  Nickel Plated 

156094

 

Air Slider,  Jøtul Iron Paint 

156093

58.  Air Cover Plate, Matte Black Paint 

156076

 

Air Cover Plate, Blue Black Enamel 

156059

 

Air Cover Plate, Jøtul Iron Paint 

156077

59.  Secondary Air Tube 

221753

60.  Baffle Plate,  Right  

104296 

61. 

Baffle Plate,  Left  

104295

62.  Airwash Manifold, inc. gasket / Matte Black Paint  156090

 

Airwash Manifold, inc. gasket / Jøtul Iron Paint 

156091

63.  Bolt, M6 x 16  Flange Head 

99625

64.  Surround Leg, Right  - Matte Black Paint 

156084

 

Surround Leg, Right - Blue Black Enamel 

156063

 

Surround leg, Right - Jøtul Iron Paint 

156085

65.  Trim,  Bottom Right - Matte Black Paint 

156088

 

Trim, Bottom Right - Blue Black Enamel 

156065

 

Trim, Bottom Right - Jøtul Iron Paint 

156089

66.  Surround Support, Right 

221733

67.  Nut, M8 Flange 

117881

68.  Bolt, M8x 25 Flange Hex 

117876

69.  Front Plate Attachment Bracket (2) 

156792

71. 

Bracket, Bottom Trim 

221770

72. 

Brick, 4.5 x 8.5 - Refractory 

221751

73. 

Brick, 3.5 x 8.5 - Refractory 

221752

74.  Surround Support, Left 

221732

75. 

Bolt, M6 x 40 Hex Head / SS 

117997

76.  Brick Retainer, Cast 

10430092

77. 

Trim, Bottom Left - Matte Black Paint 

156086

 

Trim, Bottom Left - Blue Black Enamel 

156064

 

Trim, Bottom Left -Jøtul Iron Paint 

156087

78.  Surround Leg, Left - Matte Black Paint 

156082

 

Surround Leg, Left - Blue Black Enamel 

156062

 

Surround Leg, Left - Jøtul Iron Paint 

156083

79.  Surround Panel, Breastplate, Right - Matte Black 

156080

 

Surround Panel, Breastplate, Right - Blue Black  

156071

 

Surround Panel, Breastplate, Right - Jøtul Iron 

156081

80.  Surround Panel, Breastplate,  Left - Matte Black 

156078

 

Surround Panel, Breastplate,  Left - Blue Black 

156061

 

Surround Panel, Breastplate,  Left - Jøtul Iron 

156079

81. 

Hang Tab 

224144

82.  Rope Gasket, Fbrgls - LD .250 SA  - 

Outer Air Mnfld, 30”

 129644

83.  Gasket, Flat - .125 x 8 mm  -  

Inner Air Manifold, 20”

 127215

84.  Washer, .062 x .500 

117947

85.  Riser Bar Assembly, Replacement 

156072

86.  AC  Harness  w/ Receptacle,  Replacement 

156057

87. 

Set Screw,  M6 x 10 mm - Surround adjustment  04-117720

88.  Blower Power Cord, HT - Offset Angle 

222093

89.  Wooden Knob Replacement Kit 

151991

90.  Handle Asy, Complete / Matte Black Paint 

156320

 

Handle Asy, Complete / Nickel Plated 

156321

91. 

#8 Spring Nut 

118056

92.  Fettle / Matte Black Paint 

10432092

 

Fettle / Jøtul Iron Paint 

10432085                    

93.  Bolt, M8 x 20, Flange Hex 

117875

Summary of Contents for C 350

Page 1: ...burn any other fuels Read this entire manual before you install and use this appliance Save these instructions for future reference and make them available to anyone using or servicing the fireplace insert This wood heater requires periodic inspection and repair for proper operation See this manual for specific maintenance information It is against federal regulations to operate this wood heater i...

Page 2: ... Care 17 Chimney System 18 Gaskets 19 Blower 19 Illustrated Parts Breakdown Exploded View 20 Parts Listing 21 Appendix A Door Knob Assembly 22 Baffle Plate Removal 22 Warranty Statement 23 For Your Records Record the following information to help your dealer determine what you will need should your fireplace ever require parts or service The serial number and manufacturing date are indicated on th...

Page 3: ...S Standards The Jøtul C 350 Winterport fireplace insert has been tested and listed to the following standards U S ANSI UL 1482 2011 Canada CAN ULC S627 00 Certified Safety Tests performed by ITS Intertek Testing Services Middleton Wisconsin Manufactured by Jøtul North America 55 Hutcherson Drive Gorham Maine 04038 2644 Combustion Specifications Jøtul C 350 Winterport Heat Output Range 1 11 420 to ...

Page 4: ...5 Install the Door Knob parts in the order shown in fig 21 page 22 Safety Notices BURN SOLID WOOD FUEL ONLY DO NOT BURN OTHER FUELS DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS IF THIS ROOM HEATER IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESU...

Page 5: ... 4 641 mm without Riser Bar 27 1 4 692 mm with Riser Bar Bottom Surround Trim Figure 1 Critical dimensions 2 51 mm Steel Wide Surround Panel For use with Riser Bar Optional Surrounds and Accessories Steel Wide Surround 40 x 30 Matte Black 156055 Trimable Surround 37 x 25 1 2 for Z C fireplaces 157326 Draw Down Adaptor Kit 156073 Stove Gloves 157363 Universal Gasket Kit 157050 Blower Flex Hard Wire...

Page 6: ...g type HT requirements 2100F per UL 1777 U S or ULC S635 CAN The liner must be securely attached to the insert flue collar and the chimney top Some liner manufacturers require insulation in order to achieve a UL 1777 or ULC S635 listing Check with the manufacturer of the liner being used to determine if insulation is required Insulation is recommended particularly if the chimney flue is located in...

Page 7: ...nt Riser Bar not required Min 16 from door opening 2 1 2 Figure 4 Required hearth protection if flush with combustible floor materials Riser Bar must be installed Combustible Flooring Zero clearance fireplace installation cont d Alteration of the zero clearance fireplace functionality or structure is not permitted i e firebrick or refractory panels MUST NOT be be removed to accommodate the firepla...

Page 8: ...2 mm Figure 5 Minimum clearance to combustible materials Figure 6 Mantel Clearance Detail measured from the hearth surface to the lowest mantel surface Riser Bar is not installed Add two inches to each clearance dimension when Riser Bar is used Clearance to Combustible Materials There may be no combustible materials located anywhere within 36 914 mm of the front of the fireplace insert This precau...

Page 9: ...ile is acceptable provided the tile is no larger than 8 x 12 For external chimneys one or more sides are exposed to the outside below the roof line including garages a positive connection to the first flue tile is acceptable provided the tile is no larger than 8 x 8 A 6 7 or 8 stainless steel liner extending the full height of the chimney is required for all installations where the flue tile is gr...

Page 10: ...tallation See page 16 DISCONNECT POWER BEFORE COMPLETING FIREBOX INSTALLATION Attach Fireplace Conversion Notice Plate to Rear Wall of Fireplace Masonry or Listed HT Prefabricated Chimney Cap Sealed connection to chimney cap Damper linkage removed and plate is removed or locked open Figure 8 Positive Chimney Connection Canada Installation 1 Remove the existing damper and linkage components from th...

Page 11: ... the firebox is aligned with the front edge of the Riser the Locking Pin hole will be aligned with the slot in the top of the Riser Bar cross member Insert the Locking Pin and pull the firebox out slightly proud of the fireplace face to facilitate attaching the surround panels Relocate the blower 3 Secure the flue connector to the firebox flue collar using three 1 4 x 3 4 self tapping screws Figur...

Page 12: ... Required 10 mm socket or wrench Tighten just snug enough to allow for final adjust ment when the Surround assembly is attached to the firebox Bend the perforated mounting plate down 90 as shown in Fig 14 Insert and center the bracket plate sandwiched between the firebox and the Riser Bar 5 If appropriate attach the Extended Surround Panel to the firebox With the painted side facing out engage the...

Page 13: ...asoned more than 2 years will burn too quickly to take advantage of the stove s low end efficiency strength A seasoned log will have check marks on the ends and be lighter than an unseasoned log which will show little or no check marks We recommend using a moisture meter to determine the moisture content of your wood For purposes of home heating your fuel should have a moisture content between 12 ...

Page 14: ... couple of 1 2 inch logs and add progressively more and larger logs to subsequent fires keeping the Air Control set to the fully open position It is normal for a new fireplace insert to emit odor and possibly smoke during the first few fires This is characteristic of the burn off of residues from the manufacturing process and the curing of painted surfaces Open a window near the fireplace insert t...

Page 15: ...ull open position far right Always wait a few seconds before opening the door This allows the renewed air circulation to clear un burned gases from the firebox Use a stove tool or poker to distribute the hot embers equally around the firebox Load the fuel usually with smaller logs first Keep logs behind the andirons See fig 16 Close the doors and secure the latch Wait 5 10 minutes for the fire to ...

Page 16: ...DED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE CURRENT ANSI NFPA 70 NATIONAL ELECTRICAL CODE OR CSA C22 1 CANADIAN ELECTRICAL CODE THIS UNIT IS SUPPLIED WITH A THREE PRONG GROUNDING PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG ALWAYS DISCON...

Page 17: ...materials pending final disposal If the ashes are disposed of by burial in soil or otherwise dispersed they should be kept in the closed container until all coals and cinders have thoroughly cooled IMPORTANT NEVER OPERATE THE STOVE WITH A CRACKED OR BROKEN GLASS PANEL Replace glass only with part 156069 specifically designed for the Jøtul C 350 Winterport Fireplace insert Do not use substitutes Re...

Page 18: ...s Never use a household vacuum cleaner to remove ashes Only a shop vac with a metal container is acceptable and only when you are certain the ashes are cold Inspect the firebox using a utility light inside and out for cracks or leaks Replace all cracked bricks and repair leaks with furnace cement Removing the Insert for Cleaning U S Direct connection Only 1 Disconnect the blower power cord from it...

Page 19: ...ll the dollar bill free The seal is too loose if the bill can be easily re moved Adjust the door latch and test again Gasket Replacement See the chart below for replacement gasket specifications See also fig 20 for locations 1 Remove the old gasket material with a pliers and thoroughly clean the channel with a wire brush 2 Lay out the new gasket around the channel to determine length Trim the gask...

Page 20: ...e only genuine Jøtul replacement parts Do not substitute parts from any other manufacturer See your local Authorized Jøtul Dealer or contact us directly Jøtul North America 55 Hutcherson Dr Gorham Maine 04038 Jøtul C 350 Winterport Illustrated Parts Diagram ...

Page 21: ...e Black Paint 156092 Air Slider Nickel Plated 156094 Air Slider Jøtul Iron Paint 156093 58 Air Cover Plate Matte Black Paint 156076 Air Cover Plate Blue Black Enamel 156059 Air Cover Plate Jøtul Iron Paint 156077 59 Secondary Air Tube 221753 60 Baffle Plate Right 104296 61 Baffle Plate Left 104295 62 Airwash Manifold inc gasket Matte Black Paint 156090 Airwash Manifold inc gasket Jøtul Iron Paint ...

Page 22: ...e can then be slid to one side to disengage one end from the side manifold The baffles will continue to be supported by the back ledge and the side manifolds 2 Lift and remove the Right Baffle 3 Lift and remove the Left Baffle Reassemble in the opposite order Door Knob Installation The Door Knob components are included in a sepa rate bag contained within the Miscellaneous Kit in cluded with the fi...

Page 23: ... red Over firing can also be identified by warped plates rust colored cast iron paint pigment that has turned dusty white or bubbling cracking and discolor ation of the enamel finish Misuse includes without limitation use that is not in conformance with the operating instructions contained in this owner s manual 4 Damage to enamel finish including chipping mechanical or chemical abrasion crazing s...

Page 24: ...s appliance must be installed in conformance with local and national building regulations It is important that the these instructions be carefully read and understood before beginning the installation Jøtul pursues a policy of continual product development Consequently products may differ in specification color or type of accessories from those illustrated or described in various publications ...