Jotron AS| TR7750C: Operators Manual
Operating Instructions
Page 5-21
P/N: 84748 (G)
5.9
Parameter details – receiver
5.9.1
Radio control group
Menu path:
Radio control
►
Parameter
Range
Default Details
Squelch level
-10 dBuV to +30
dBuV
0 dBuV
Squelch level
This squelch level is the level for the digital
noise compensated squelch.
Operation mode
Main | Norm
Norm
A
main
radio will enter into standby if an
alarm is detected by the internal BITE
system.
A
norm
radio will continue operation (if
possible) even if a failure is detected.
In a main / standby configuration, the main
radio is set to
Main
and the standby radio is
set to
Norm
. In this way the control can
automatically be transferred to the standby
radio by using the available alarm output and
select input on the radios.
Modulation
FM
FM
Select the modulation type / waveform to
use.
Availability depends on radio specifications.
Alarm
On | Off
Off
This setting force the radio into alarm state
(forced alarm) if set to
On
.
Used for simulations, or to force a radio to
signal an alarm in order to select a backup
(standby) radio.
Standby
On | Off
Off
This setting force the radio into standby state
(forced standby) if set to
On
.
Used to manually set a radio to standby.
Table 5.9-1, Radio control group, receiver
Summary of Contents for RA-7203C
Page 1: ......
Page 7: ......
Page 32: ...Jotron AS TR7750C Operators Manual Installation Page 4 4 P N 84748 G...
Page 44: ...Jotron AS TR7750C Operators Manual Installation Page 4 16 P N 84748 G...
Page 63: ...Jotron AS TR7750C Operators Manual Operating Instructions Page 5 13 P N 84748 G...
Page 88: ......