Jotron AS| TR7750C: Operators Manual
Installation
Page 4-12
P/N: 84748 (G)
Menu path:
RX config ►
Parameter
Range
Default
Details
Squelch
SqOut output
Closed | Open |
Closed on busy|
Open on busy
Closed on
busy
Set the behavior of the SqOut output (AUX2,
pin 1 and pin 2).
Squelch
RxBusy output
Closed | Open |
Closed on busy|
Open on busy
Closed on
busy
Set the behavior of the RxBusy output
(REM, pin 5).
Table 4.6-7, Squelch output configuration
4.6.5
Alarm and Select signals transmitter and receiver
Figure 4.6-4, Alarm and select signals, transmitter
The alarm signals are outputs used to signal that the radio units has detected an alarm internally. The
Select signal is used to select or deselect (inhibit) a particular unit. By deselecting a unit, the unit will
enter into standby and can not be used for radio communication. However, all other functionality of
the radio units is operational when the radio is in the standby state.
The pinout and signals are equal on the transmitter and the receiver unit, except the ALARM (REM,
p.7) pin. This pin has a fixed +5V pull-up on the receiver, while the pull-up is configurable on the
transmitter.