Jotron AS| TR7750C: Operators Manual
Installation
Page 4-21
P/N: 84748 (G)
Figure 4.7-4, Main / Backup transmitter
Step
Description
Reference
1
Connect the alarm_out signal (p.1,2) from AUX1 on the main
transmitter to the select_in signal (p.3.6) on AUX1 on the standby
transmitter. The connection can be done via a distribution panel or
by making a special with RJ45 connectors in each end. The cables
used should be of the same quality as a CAT5E network cable and
the screen should be connected in the plugs.
– AUX1 connector
2
Set
Alarm config, Alarm pin pullup
to
Enabled
(default)
– Interface config group
3
Set
Alarm config, Select polarity
to
Low
(default)
– Interface config group
4
Set the main transmitter
Operation mode
to
Main
– Radio control group
5
Set the backup transmitter
Operation mode
to
Norm
(default)
– Radio control group
6
Connect separate antennas to the two transmitters.
Alternatively use an external antenna change over unit (ACU) in
order to switch the antenna between the main and standby
transmitters. The antenna change over unit can be controlled by
the alarm signal on the main unit
Table 4.7-4, Main/backup configuration, transmitters