19
User and Installation Manual
Compact MPA
4.12 CABINET POWER
TERMINAL CONNECTIONS
4.12.1 AC + DC VERSION
The primary power source for the Compact MPA Cabinet is 230VAC with 24VDC as backup.
TB1
TB2
1
230VAC
Live
1
24VDC
2
2
3
3
4
230VAC
Neutral
4
24VDC (fuse)
5
5
0VDC
6
6
7
PE
GND
7
8
8
0VDC (fuse)
9
9
PE
GND
TB3
10
1
MPA 24VDC backup (supplied from 1671)
2
MPA 0VDC backup (supplied from 1671)
4.12.2 AC + AC VERSION
The primary power source for the Compact MPA Cabinet is 230VAC with additional 230VAC as backup.
TB1
TB2
1
230VAC
Live
1
2230VAC
Live
2
2
3
3
4
230VAC
Neutral
4
230VAC
Neutral
5
5
6
6
7
PE
GND
7
PE
GND
8
8
9
9
TB3
10
1
MPA 24VDC backup (supplied from 1671)
2
MPA 0VDC backup (supplied from 1671)
4.13 CABINET POWER
FAILURE RELAY CONNECTIONS
The power failure relays K1 and K2 are DPDT relays with one pole on 11, 12 and 14 and the other pole on 21, 22 and 24.
K1
K2
11
Primary power fail – Common contact
21
11
Secondary power fail – Common contact
21
12
Primary power fail – NC contact
22
12
Secondary power fail – NC contact
22
14
Primary power fail – NO contact
24
14
Secondary power fail – NO contact
24
Summary of Contents for MPA 1600
Page 21: ...22 User and Installation Manual Compact MPA DNH HP15T...
Page 51: ...52 User and Installation Manual Compact MPA 9 2 WALL BRACKET KIT...
Page 53: ...54 User and Installation Manual Compact MPA 9 3 COMPACT MPA CABINET EXTERNAL CONNECTION...
Page 54: ...55 User and Installation Manual Compact MPA...
Page 62: ...www jotron com...