18
induction heating
Induction Heater JH400
Connection of electric supply
The heater is designed for 208-240 V, 50-60
Hz. It is fitted with a plug that allows it to be
plugged to a wall outlet . The power supply
must have a ground connection, and it must
also be protected with a fuse as follows:
• When using up to step 4 of the output
power, the supply can be protected with a
10 A fuse .
• When using max (step 5) of the output
power, the supply must be protected with a
16 A fuse .
The connection of JH400 to the electrical
supply is done as follows:
• Plug JH400 to a wall outlet .