background image

2

INTRODUCTION

Jordan Controls, Inc., designs, manufactures, and tests

its products to meet national and international stan-

dards. For these products to operate within their

normal specifications, they must be properly installed

and maintained. The following instructions must be

followed and integrated with your safety program

when installing, using, and maintaining Jordan Controls

products:
Read and save all instructions prior to installing,

operating, and servicing this product.
If any of the instructions are not understood, contact

your Jordan Controls representative for clarification.
Follow all warnings, cautions, and instructions marked

on, and supplied with, the product.
Inform and educate personnel in the proper installa-

tion, operation, and maintenance of the product.
Install equipment as specified in Jordan Controls

installation instructions and per applicable local and

national codes. Connect all products to the proper

electrical sources.
To ensure proper performance, use qualified personnel

to install, operate, update, tune, and maintain the

product.
When replacement parts are required, ensure that the

qualified service technician uses replacement parts

specified by Jordan Controls. Substitutions may result

in fire, electrical shock, other hazards, or improper

equipment operation.
Keep all actuator protective covers in place (except

when installing, or when maintenance is being per-

formed by qualified personnel), to prevent electrical

shock, personal injury, or damage to the actuator.

WARNING

Before installing the actuator, make sure that it is

suitable for the intended application. If you are unsure

of the suitability of this equipment for your installation,

consult Jordan Controls prior to proceeding.

WARNING - SHOCK HAZARD

Installation and servicing must be performed only

by qualified personnel.

WARNING - ELECTROSTATIC DISCHARGE

This electronic control is static-sensitive. To

protect the internal components from damage

caused by static discharge, never touch the printed

circuit cards without being statically protected.

RECEIVING INSPECTION

Carefully inspect for shipping damage. Damage to the

shipping carton is usually a good indication that it has

received rough handling. Report all damage immedi-

ately to the freight carrier and Jordan Controls, Inc.
Verify that the items on the packing list or bill of lading

agree with your own.

STORAGE

If the actuator will not be installed immediately, it

should be stored indoors in a clean, dry area where

the ambient temperature is not less than -20° F. The

actuator should be stored in a non-corrosive environ-

ment. The actuator is not sealed to NEMA 4 until the

conduit entries are properly connected.

EQUIPMENT RETURN

A Returned Goods authorization (RG) number is

required to return any equipment for repair

. This

must be obtained from Jordan Controls. (Telephone:

414/461-9200) The equipment must be shipped,

freight prepaid, to the following address after the RG

number is issued:
Jordan Controls, Inc.

5607 West Douglas Avenue

Milwaukee, Wisconsin 53218

Attn: Service Department

To facilitate quick return and handling of your equip-

ment, include:

RG Number on outside of box

Your Company Name, Contact Person, Phone/Fax #

Address

Repair Purchase Order Number

Brief description of the problem

GENERAL INFORMATION

Summary of Contents for SM-1715

Page 1: ...eral Actuator Description 3 Basic Models 3 Specifications 4 5 Actuator 4 Options 5 Installation 5 6 Typical Wiring Diagrams 7 8 Start Up 9 11 Troubleshooting 12 13 Parts Identification 14 16 Parts Lis...

Page 2: ...or make sure that it is suitable for the intended application If you are unsure of the suitability of this equipment for your installation consult Jordan Controls prior to proceeding WARNING SHOCK HAZ...

Page 3: ...wise DC Direct Current F Degrees Fahrenheit G Earth Ground Hz Hertz in lbs Inch Pounds kg Kilogram L Line power supply lbs Pounds Force LVDT Linear Variable Differential Transformer mA Milliamp mfd Mi...

Page 4: ...ght Approximately 40 lbs 18 1 kg Enclosure Materials Cast aluminum alloy Non Rotating When Motor Runs Handcrank Gear Ratio 1003 1 Lubrication Type Permanently lubricated Gearing Spur gearing Hold on L...

Page 5: ...actuator is directly coupled to a drive shaft a Jordan Controls type coupling is recommended The output shaft is also available with a splined output for standard drive arms and linkage components to...

Page 6: ...iling codes by qualified personnel Fusing must be installed in line power and should be of the slow blow type Wiring should be routed to the actuator through the two conduit openings Generally one con...

Page 7: ...ng SM 1715 SERIES ACTUATOR Notes 1 Optional remote three phase reversing starter shown 2 Caution Care must be taken in properly phasing position and torque limit switches with respect to clockwise and...

Page 8: ...A into a 200 ohm impedance 0 to 5 or 0 to 10 Vdc into a 100 000 ohm impedance 6 The EC 10852 is for use with the AD 8130 servo amplifier with LVDT voltage feedback The EC 10852 is used as the HI and L...

Page 9: ...turn c Rotate Cam 2 CW to increase the actuator s total travel range or CCW to decrease the travel range d Hold the cam in place and tighten screw 2 6 Electrically operate the actuator to its CW limit...

Page 10: ...Four different cams are supplied with each characterized assembly The cams are printed on both sides and may be flipped over to reverse the character ization action in relation to the output shaft ro...

Page 11: ...tively lay out additional x axis scale as shown in figure 3 on page 13 Use both sets of values when plotting cam shape in step 3 3 Calculate outputs rise in cam for 5 or 10 increments in input for ent...

Page 12: ...j Correct power input problem k Amplifier defective k Replace amplifier l Amplifier is in Loss of Signal l Check command signal to verify signal greater than 3 8 mA is present m Amplifier deadband is...

Page 13: ...gnal c Reduce noise Also ensure that command signal wiring is shielded with shield grounded at source common only a Pot not aligned with end of travel extremes and is being driven through dead region...

Page 14: ...14 Parts Identification GEAR LOCATION Front View Letters in balloons refer to gear assembly drawing on page 15 Side View Numbers in balloons refer to parts identification list on pages 17 18...

Page 15: ...15 Parts Identification GEAR ASSEMBLY Numbers in balloons refer to parts identification list on pages 17 18...

Page 16: ...16 LIMIT SWITCH COMPARTMENT Numbers in balloons refer to parts identification list on pages 17 18 Parts Identification...

Page 17: ...ring Handcrank 17B 003813 011 1 23 18 19 20 21 6 7 10 12 Motor See Motor Selection on p 20 Pinion Gear See Gear Chart on page 20 Gear Ass y 2nd Stage See Gear Chart on page 20 17 13 27 Worm Gear 16A 0...

Page 18: ...6034 005 31 61B 026406 003 16B 015633 004 65B 016034 008 60 61B 026407 002 16B 017896 001 65B 016034 007 12 61B 026406 003 16B 015633 001 65B 016034 001 24 61B 026406 003 16B 105633 003 65B 016034 003...

Page 19: ...t enough to prevent backdriving 4 While handcranking against the load increase the load until motor backdriving occurs Maintenance TORQUE LIMIT SWITCH ALIGNMENT The torque limit switches are factory s...

Page 20: ...power to the actuator 2 Remove screws washers and rear cover 3 Remove three screws holding potentiometer and disc to housing 4 Pull potentiometer and disc out of housing 5 Measure location of gear fr...

Page 21: ...o available to allow length to vary from 6 to 10 inches 152 to 254 mm In this case the adapter clevis has rod ball ends with lubrication fittings 3 Weight of all linkage components including cus tomer...

Page 22: ...oot face or side mounted 3 Overall depth is approximately 13 inches 330 mm on the SM 1715 three phase model 4 The output shaft is available in a one inch 25 4 mm diameter with 1 4 inch 6 35 mm square...

Page 23: ...23...

Page 24: ...ed for preparation of drawings or fabrication of installation mounting Current installation dimension drawings are available upon request JORDAN CONTROLS INC 5607 West Douglas Avenue Milwaukee Wiscons...

Reviews: