Fig. 28: Gently unscrew the ionising pipe,
gripping it at the base (green part).
If the operation is difficult to perform, pull
slightly the earthing spring so that it is not
in contact with the surface of the tube.
Fig. 29: Pull off the outer mesh from the
tube. If this is difficult to do, turn the mesh
around the glass while pulling to remove it.
Fig. 30: Clean the glass using a damp
cloth.
Do not use liquid cleaners,
sprays, soap or other
products.
Check that the tube is in good
conditions: there must not be
any cracks or other damage;
otherwise it must be replaced.
The presence of a whitish layer on the perforated metal sheet inside the glass indicates
the need to replace the pipe. The tube must usually be replaced within 18 months of
use.