background image

PRODUCT

P  1/ 9

Model No.

Description

C

ONCEPT AND MAIN APPLICATIONS 

S

pecification

Standard equipment

Optional accessories

DCL140, DCL180
Cordless Cleaner

Models DCL140 and DCL180 are handy cordless cleaners of cloth filtration type 

powered by Makita Li-ion battery;

DCL140 by battery of BL1415 (1.3Ah), BL1415N (1.5Ah), BL1415NA (1.5Ah), 

BL1430 (3.0Ah), BL1430A (3.0Ah) or BL1440 (4.0Ah)

DCL180 by battery of BL1815 (1.3Ah), BL1815N (1.5Ah), BL1820 (2.0Ah), 

BL1830 (3.0Ah), BL1840 (4.0Ah) or BL1850 (5.0Ah).

With the main benefits described below, optimum for cleaning operations 

of contractors already having the Makita 14.4V or 18V:

Strong suction power and Large dust capacity for heavy-duty applications

Low noise design ideal for quiet cleaning operation in job sites among

    residential areas

Rubberized soft grip for reduced hand fatigue even in long continuous use

Note: 

The standard equipment may vary by country or model variation.

Nozzle assembly (T-nozzle)

Pipe (Extension pipe)

Sash nozzle

Sash nozzle holder

Dimensions: mm (")

Width (W)
Height (H)

Length (L2)

Length (L1)

981 (38-5/8) 999 (39-1/4)

458 (18)

476 (18-3/4)

114 (4-1/2)

152 (6)

DCL140

DCL180

*1 

with Battery BL1430  

*2

 with Battery BL1830  

*3

 with Battery, without T-nozzle, Extension pipe and Sash nozzle

*4

 with Battery BL1415/BL1415N  

*5

 with Battery BL1815/BL1815N/BL1820  

Nozzle assembly

(for rug/ carpet)

Shelf brush

Flexible hose

Round brush

Filter

Pre-filter

Max. sealed suction: kPa (mmH

2

O)

Max. air flow: m

3

/minute

Battery

Dust capacity: mL

Cell
Voltage: V
Capacity: Ah

Continuous use (approx.)

on a single full battery charge: minute

650

Suction power: W

Weight according to

EPTA-Procedure 01/2003

*

3

: kg (lbs)

Specification

Model

14.4

18

1.2

3.6 (360)

3.2 (320)

Li-ion

30

25

20

*

2

20

*

1

1.2 (2.6)

*

4

1.2 (2.7)

*

5

DCL140

DCL180

Charging time (approx.): min.

T

OFFICIAL USE 

for ASC & Sales Shop

ECHNICAL INFORMATION

Energy capacity: Wh

1.3, 1.5, 3.0, 4.0

15, 15, 22, 36

with DC18RC

1.3, 1.5, 2.0, 3.0, 4.0, 5.0

19, 22, 44, 58

24, 27, 36, 54, 72, 90

15, 15, 24, 22, 36, 45

with DC18RC

For DCL140

Li-ion battery BL1415

Li-ion battery BL1415N

Li-ion battery BL1415NA

Li-ion battery BL1430

Li-ion battery BL1430A

Li-ion battery BL1440

For DCL180

Li-ion battery BL1815

Li-ion battery BL1815N

Li-ion battery BL1820

Li-ion battery BL1830

Li-ion battery BL1840

Li-ion battery BL1850

Fast charger DC18RC

Charger DC18SD

Charger DC24SC

Automotive charger DC18SE

Four port multi charger DC18SF

L2

L1

H

W

1.3

L1: without T-nozzle and Extension pipe

L2: with T-nozzle and Extension pipe

Filter (factory-mounted)

Pre-filter (factory-mounted)

Summary of Contents for DCL140

Page 1: ...ry BL1830 3 with Battery without T nozzle Extension pipe and Sash nozzle 4 with Battery BL1415 BL1415N 5 with Battery BL1815 BL1815N BL1820 Nozzle assembly for rug carpet Shelf brush Flexible hose Rou...

Page 2: ...ly steps Fig 1 2 Separate Capsule from Housing by pulling it in the direction of the arrow 3 Remove 4x18 Tapping screw and Flat washer 4 Valve can now be disassembled from Capsule 4x18 Tapping screw F...

Page 3: ...f Motor assembly Fan cover 1 Assemble Fan cover to Motor assembly Fig 4 Motor assembly Fig 4 Housing R 3x16 Tapping screw 7 pcs Fig 2 Fig 3 Stay Remove Housing R by unscrewing seven 3x16 Tapping screw...

Page 4: ...ing L as illustrated below Compression spring 4 Switch lever Housing L rib Fig 7 Rubber ring Switch Fan cover Housing L The assembled Rubber ring has to fully cover the Base section of Motor assembly...

Page 5: ...ssembly with Controller and Switch fix the Lead wires securely by pushing the Lead wires deep into the slit of Lead wire holder until they stop Lead wires of Motor assembly Lead wire holder Controller...

Page 6: ...of Housing L notch of Stay Stay 3x16 Tapping screw 7 pcs 1 Remove Sponge sheet 50 50 from the vent frame of Housing R L 2 Remove sponge dust remaining on the pins of the vent frame ASSEMBLING Fig 12 1...

Page 7: ...9 Repair 4 MAINTENANCE Fig 13 When Housing is disassembled clean up the inside of the machine by blowing off the dust that settles on DC Motor Fan Housing etc with air duster for longer tool life Fig...

Page 8: ...the minus terminal of Motor assembly Then assemble Motor section to Housing L with the plus terminal of Motor assembly on Switch side top side Note Make sure that the wire connecting portion of each r...

Page 9: ...Pass Lead wires between Rib and Inner wall of Housing Red marking Controller Housing L side Housing R side Switch Connect Receptacles to Switch terminals with the wire connecting portion of each rece...