17
2.3 Assembly steps
F
ig
. 11
F
ig
. 15
F
ig
. 16
F
ig
. 13
11.
Remove the galvanised protection plate on the fan support
(bottom of fireplace exchanger).
12.
If ducting is provided for, using a hammer knock out the
precut sheets on the top hot air outlets (
F
ig
. 11
) and insert
the special connections to test before inserting the boiler
(optional). The air connections can also be applied with the
fireplace fitted, by removing the dampers.
13.
Place the exchanger in the right position and make sure
the fan does not suck air between the exchanger and the
fireplace base.
14.
For the hot air ducting, connect the air pipes by means of the
fume exhaust.
15.
Insert the air ducting pipes on the special connection
(optional) and fix them with the pipe clamp (optional).
16.
Insert the connection and pipe in the support and turn to
secure the connection (
F
ig
. 12
).
N.B. It is advisable to try
fitting the connections before inserting the fireplace.
17.
Insulate the top part of the exchanger.
18.
Lower the stainless steel pipe all the way into the special
support on the exchanger, operating from the fume exhaust
or, if possible, from the outside, forcing it down with hands
or using a curved iron (
F
ig
. 8
) to hermetically close the fume
passage.
19.
Position the controller, securing it to the fireplace structure
at the front or the side (
F
ig
. 14
and
F
ig
. 15
).
20.
Bend the bottom edge of the fan down to prevent vibration
and noise (
F
ig
. 16
), insert it in the space and secure with the
special screws.
21.
Fit the prebox and secure it with self-tapping screws.
22.
Plug any space at the front between the exchanger and the
fireplace with the mesh, securing it with self-tapping screws
or other material suitable for the fireplace, mortar, bricks,
marble, etc. (
F
ig
. 13
).
17
F
ig
. 12
F
ig
. 14
Summary of Contents for UNIVERSAL JOLLY Maxi