19
ENGLISH
The external air intakes must be made so that they cannot get accidentally covered and if they have an insect
protection mesh they must be cleaned periodically to prevent clogging with dust and dirt, especially in periods with intense
pollen concentrations.
NOTE
As indicated in the national reference standard UNI
10683, the product can not be installed in rooms
with a volume of under 15 m
3
.
NOTE
CHAP.07 POSITIONING AND CONNECTIONS FOR THE INSTALLER
07.1
SETTING UP OF EXTERNAL AIR INTAKES AND ELECTRIC CURRENT
The device must only be installed indoors and on surfaces
that can support the load. If the existing construction does not
meet this requirement, it will be necessary to take appropriate
measures (e.g. installing a load distribution plate). The appliance
must be installed in an area where the appliance itself, gas
exhaust pipes and flue can be easily accessed for maintenance.
Fig. 1
illustrates minimum distances that must be observed, all
measures must be in mm.
The lateral distance from the adjacent wall, according to
installation, is to be maintained on both sides.
1.
Electrical socket
2.
External air inlet (see chap. 07.4)
3.
Comburent air intake
4.
Rear panel
5.
Side panel
Front view
View from
above
Bear in mind that the minimum distances from
inflammable materials are:
Minimum air distance from inflammable side wall (A): 150 mm
Minimum air distance from inflammable rear wall (B):
100 mm
Frontal air distance from inflammable material (C): 900 mm
as indicated in
CHAP.06.1 - HOMOLOGATION
NOTE
- View from the back (main quotes for carrying out installation)
Fig.1
max 1250
B
A
C
1
4
2
5
3
3 di 3
Efrem
ASSIEME GENERALE AMBRIA2
19/09/2016
607590_0.idw
607590_0
Descrizione
Disegnato
Data creazione
Nome file
Codice disegno
Foglio n°
Scala
Anagrafica articolo
X : X
La JOLLY-MEC caminetti S.p.A. si riserva a termini di legge la proprietà del presente disegno con divieto di riprodurlo o comunicarlo a terzi senza sua autorizzazione
L E A D E R N E L R I S C A L D A M E N T O
Rev.
0
18
10
73
84
13
85
0
12
83
13
230,8
1,8
255,2
487,8
19
2
36
4,
5
60
90
58
461,5
56,2
56,2
349
179,7
109
Summary of Contents for AMBRIA2 10 kW
Page 18: ...18 06 4 DIMENSIONS All measurements are in mm C A B AMBRIA2 10 kW A 461 5 B 1073 C 487 8 ...
Page 37: ...37 ENGLISH NOTES ...
Page 38: ...38 NOTES ...
Page 39: ...39 ENGLISH NOTES ...