ASSEMBLY INSTRUCTIONS
Pag. 12
ELECTRICAL CONNECTIONS
CONTROL UNIT
ELECTRICAL DEVICE - DETAILS
Connect the 220 - 230 V line to terminals 1 - 2 on the con-
trol panel and the earth cable to screw on the control panel
casing.
Connect the fireplace thermostat cable to terminals 5 - 6 on
the control panel.
Connect the fan to terminals 7 - 8 and to the earth screw on
the control panel casing.
Make sure you observe the relevant safety standards when
wiring up the various components.
If you need to replace the earth cable (code “Cable/GND”),
please obtain the new one from your local dealer or direct
from the manufacturer
Take great care when making all electrical connections
through its devices. Always insert properly.
The luminous led on the control panel is always on when the
fan is working. You may also find that the luminous led is on
when the control panel is switched to OFF, as this led is
directly linked to the operation of the fan, which remains on
as long as the contact thermostat provides the OK signal.
1
VENTILATORE
CENTRALINA
2 3 4
5 6 7 8
TERMOSTATO CAMINO
CUSTODIA CENTRALINA
linea 220 - 230 V
terra
2
1
3
4
OFF
MIN
MED
MAX
ESTATE
INVERNO
Control unit
Control unit case
Fireplace thermostat
Ventilator
Line 220/230V
earth
1
- Fireplace thermostat
2
- Insulation braid
3
- Connecting ceramic device
4
- Protection sump