Pag. 11

C A M I N E T T I   S . P. A .

leader nel riscaldamento

CLADDING

Start assembling the cladding and the relative hood: put the
control unit in a suitable position.
A window must be fitted to allow for the feeding of the
humidifier. It is necessary creating an air grille in the hood
(min. 10x30 cm) without any filters, nets or other closures:

IMPORTANT

Should the installation of the fireplace be done in a basement,  fit
the air intakes 20x20 (or diam. 20) outside, by using flexible pipes
and creating an air intake, under the fireplace, connecting  the
internal room with outside to allow the ventilator to intake air from
outside (solution A).

Otherwise, make a hole in the hood, communicating with
outside, diam. 150 (solution B), leaving the air passing through
the base of the cladding (min. meas. 10x30).

the grill must be connected to the air intake without any pipe
connection (see example).
A gap must be left between the fireplace and the cladding
to allow for the ventilator  to get the air.

A

B

4

linea 220V

Hood ventilation grille10x40

Summary of Contents for AERJOLLY 100

Page 1: ...C A M I N E T T I S P A leader nel riscaldamento AERJOLLY WOOD BURNING FIREPLACE ASSEMBLY AND MAINTENANCE INSTRUCTIONS keep in a safe place PATENTED MODEL...

Page 2: ...onsulted whenever necessary as the directions it contains are important for safety during the installation use and maintenance of your fireplace Incorrect installation can lead to injury to people or...

Page 3: ...es Pag 5 Positioning of the air intake and electricity Pag 6 Positions to be followed during installation Pag 7 Assembly procedure Pag 8 9 Glasses assembly procedure Pag 10 Cladding Pag 11 Electrical...

Page 4: ...a room thermostat It also has a manually fed humidifier to avoid health problems such as a dry throat headaches various allergies etc fragrant balsamic essences can be added mixed with the water The f...

Page 5: ...lined to prevent the fumes from cooling and the consequent formation of condensation the same goes for the exposed section from the roof to the chimney pot We recommend using unlined stainless steel...

Page 6: ...ry panel 5 Rear refractory panel 6 Cast iron grille 7 Front sheet 8 Deflector 9 Fume register 10 Fume register push rod 11 Friction with screws and nogs 12 Humidifier topping up 13 Cap 1 2 14 Steel at...

Page 7: ...lexible pipe 100 80 120 100 10 Tube clamps 11 Glass wool blanket for air pipes 12 Rock wool blanket for flue 13 Box with automatic closure for external air intake 14 Box for external air intake holder...

Page 8: ...the wall by about 50 70 cm to allow for the electrical connections We recommend respecting the indicated measures If the fireplace is to have a side seat the electrical plant must be installed on the...

Page 9: ...70 Pag 7 C A M I N E T T I S P A leader nel riscaldamento POSITIONS TO BE FOLLOWED DURING INSTALLATION 60 78 60 88 60 108 78 79 21 88 91 28 108 102 28 WALL POSITIONING MOD 80 MOD 100 CORNER POSITIONI...

Page 10: ...tube with the top up fitting must run parallel with the boiler fitting The tank must be fixed on the inside or outside of the hood Extend the tube as required 15 Register friction 16 Fit the fume regi...

Page 11: ...ent forming a well polished funnel see example Otherwise make a hole in the flue see drawing 16 15 17 20 19 OFF MIN MED MAX ESTATE INVERNO 20 EXAMPLE OF FLUE WITH UNIVERSAL FITTING Flue Hole for walli...

Page 12: ...t close properly i e not aligned or one sticking out loosen the screw responsible for the misalignment and compensate with silicone FIREGUARD WITH DOORS AND LATCH DOORS OPTIONAL Apply a layer of sili...

Page 13: ...fit the air intakes 20x20 or diam 20 outside by using flexible pipes and creating an air intake under the fireplace connecting the internal room with outside to allow the ventilator to intake air fro...

Page 14: ...our local dealer or direct from the manufacturer Take great care when making all electrical connections through its devices Always insert properly The luminous led on the control panel is always on wh...

Page 15: ...of tube clamps These tubes must be insulated in order to guarantee top per formance of the fireplace These should thus be fully lined with glass wool blankets min 3 cm thick Never use plastic tubes to...

Page 16: ...f fibreglass Plumb as shown in the figure A door must be fitted on the left of the hood to allow for inspection of the valves and electrical coil The water temperature gauge must be built into the hoo...

Page 17: ...g grilles on air intakes which could stop the air flow It is advisable the use of a wide net AERJOLLY MAINTENANCE Routine and systematic upkeep is essential to ensure top efficiency and max heat outpu...