ASSEMBLY INSTRUCTIONS

Pag. 14

BOILER HOOD 

The boiler hood is a 2 mm stainless steel back-boiler,

pre-tested at  4,5 ate pressure, available in two versions: 60

or 90 litres.

It produces hot water at no extra charge, as it exploits the

heat of the fumes (or using electricity).

The hood contains 60-90 litres of water, which heats up

quickly  at 60 - 70° (it depends on the type of fireplace) and

easily meets a normal family's requirements.

In 40 - 60 minutes at normal fire burning, the water

temperature can reach 60 - 90°C.

The size of the back-boiler hood makes it suitable for all

fireplace models:

- Aerjolly

- Aerjolly combinati 

- Universaljolly aria forzata e tradizionali

- Superjolly

The boiler hood can produce hot water in summer, working

when the fireplace is not being used thanks to an electrical

heating element: consumption levels are the same as the

ones of a normal boiler.

BOILER HOOD ASSEMBLING INSTRUCTIONS

Place the boiler hood on the fireplace flue and fix to the top

of the flue using a stainless steel tube.

Insulate the boiler hood with a layer of fibreglass.

Plumb as shown in the figure.

A door must be fitted on the left of the hood to allow for

inspection of the valves and electrical coil.

The water temperature gauge must be built into the hood

and be easily visible.

An omnipolar switch must be used for the electrical coil.

HINTS AND UPKEEP

The efficiency of the boiler hood depends on the type of

fireplace, the quality of the firewood and the aperture of the

fume register. The risk of hood overtemperature is controlled

by the vent valve that ensures the temperature of the water

doesn't exceed 95°C by discharging the hot water. If you

find water escaping from these valves, check the pressure

(this should be 2 - 2.5 bar). Adjust the pressure  using the

pressure reducing valve.

Cold
water intake

Safety
valve drain

Hot water
delivery 

Hood emptying

Boiler hood

Fibreglass
insulation

Ball valve to drain
system to avoid risk
of frozen pipes 

Pressure reducing
valve (recommended
setting: 1.8 - 2 bar)

Heat vent valve

3 bar
safety valve

Sleeve

4 bar safety valve (extra,
do not connect to drain)

JOLLY vent valve

Water temperature
gauge

Electrical resistance,
connect to omnipolar
switch (optional)

We recommend using an
expansion tank to avoid
sudden variations in pressure
(optional)

600/900

200

440

Summary of Contents for AERJOLLY 100

Page 1: ...C A M I N E T T I S P A leader nel riscaldamento AERJOLLY WOOD BURNING FIREPLACE ASSEMBLY AND MAINTENANCE INSTRUCTIONS keep in a safe place PATENTED MODEL...

Page 2: ...onsulted whenever necessary as the directions it contains are important for safety during the installation use and maintenance of your fireplace Incorrect installation can lead to injury to people or...

Page 3: ...es Pag 5 Positioning of the air intake and electricity Pag 6 Positions to be followed during installation Pag 7 Assembly procedure Pag 8 9 Glasses assembly procedure Pag 10 Cladding Pag 11 Electrical...

Page 4: ...a room thermostat It also has a manually fed humidifier to avoid health problems such as a dry throat headaches various allergies etc fragrant balsamic essences can be added mixed with the water The f...

Page 5: ...lined to prevent the fumes from cooling and the consequent formation of condensation the same goes for the exposed section from the roof to the chimney pot We recommend using unlined stainless steel...

Page 6: ...ry panel 5 Rear refractory panel 6 Cast iron grille 7 Front sheet 8 Deflector 9 Fume register 10 Fume register push rod 11 Friction with screws and nogs 12 Humidifier topping up 13 Cap 1 2 14 Steel at...

Page 7: ...lexible pipe 100 80 120 100 10 Tube clamps 11 Glass wool blanket for air pipes 12 Rock wool blanket for flue 13 Box with automatic closure for external air intake 14 Box for external air intake holder...

Page 8: ...the wall by about 50 70 cm to allow for the electrical connections We recommend respecting the indicated measures If the fireplace is to have a side seat the electrical plant must be installed on the...

Page 9: ...70 Pag 7 C A M I N E T T I S P A leader nel riscaldamento POSITIONS TO BE FOLLOWED DURING INSTALLATION 60 78 60 88 60 108 78 79 21 88 91 28 108 102 28 WALL POSITIONING MOD 80 MOD 100 CORNER POSITIONI...

Page 10: ...tube with the top up fitting must run parallel with the boiler fitting The tank must be fixed on the inside or outside of the hood Extend the tube as required 15 Register friction 16 Fit the fume regi...

Page 11: ...ent forming a well polished funnel see example Otherwise make a hole in the flue see drawing 16 15 17 20 19 OFF MIN MED MAX ESTATE INVERNO 20 EXAMPLE OF FLUE WITH UNIVERSAL FITTING Flue Hole for walli...

Page 12: ...t close properly i e not aligned or one sticking out loosen the screw responsible for the misalignment and compensate with silicone FIREGUARD WITH DOORS AND LATCH DOORS OPTIONAL Apply a layer of sili...

Page 13: ...fit the air intakes 20x20 or diam 20 outside by using flexible pipes and creating an air intake under the fireplace connecting the internal room with outside to allow the ventilator to intake air fro...

Page 14: ...our local dealer or direct from the manufacturer Take great care when making all electrical connections through its devices Always insert properly The luminous led on the control panel is always on wh...

Page 15: ...of tube clamps These tubes must be insulated in order to guarantee top per formance of the fireplace These should thus be fully lined with glass wool blankets min 3 cm thick Never use plastic tubes to...

Page 16: ...f fibreglass Plumb as shown in the figure A door must be fitted on the left of the hood to allow for inspection of the valves and electrical coil The water temperature gauge must be built into the hoo...

Page 17: ...g grilles on air intakes which could stop the air flow It is advisable the use of a wide net AERJOLLY MAINTENANCE Routine and systematic upkeep is essential to ensure top efficiency and max heat outpu...

Page 18: ......

Page 19: ......

Page 20: ...A M I N E T T I S P A leader nel riscaldamento JOLLY MEC Caminetti s p a 24060 Telgate BG Italy via Fontana 2 Tel 39 035 830247 Fax 39 035 833389 web www jolly mec it E mail info jolly mec it 06 2003...

Reviews: