background image

ASSEMBLY INSTRUCTIONS

Pag. 8

ASSEMBLY PROCEDURE

The fireplace is dispatched on pallets (see drawing).
Assembling and moving are easier if the fireplace is
emptied, in order to make its weight lighter.

1

- Place the boiler on the ground or lift using a crane

and fix the legs using the screws provided

2

- Place the fireplace in its final position (pag. 7)

3

- Connect the flue (see pag. 3)

to the universal fitting

4

- Connect the power cable between the fan 

and the control panel (see pag. 12)

5

- Apply a line of silicone to the fan, place it in its proper

seat and then  secure using the screws provided

6

- Assemble  the tray holder bottom

7

- Right  refractory panel

8

- Left refractory panel

9

- Rear  refractory panel

10

- Front sheet

11

- Cast iron grille

12

- Ash tray

13

- The deflector must be hanged with a front 

inclination for a max. rendering

14

- Connect the stainless steel flexible tube to one of the

two fittings on the humidifier tank. Close the one not
used with the plug provided. The flexible tube with the
top-up fitting must run parallel with the boiler fitting.
The tank must be fixed on the inside or outside of the
hood. Extend the tube as required

15

- Register friction

16

- Fit the fume register so that the name JOLLY MEC 

is horizontal when the register is closed. You must
be able to extract the register easily in order to clean
the flue by extracting the rod

17

- Fume register push rod

18

-

Tubi flessibili per la distribuzione dell’aria. Bloccare i
tubi con una fascetta stringitubo, coibentarli per tutto
il percorso con lana di vetro anche all’interno della
cappa, evitare il contatto con legno (Se prevista la
canalizzazione dell’aria, vedi esempio pag. 13)

19

- Before creating the hood, make sure the two tubes

leave the boiler, securing them with mortar or silicone:
open the fins that block the grill frame as far as they
can go and then fix the grill frame with silicone
between this and the wall (make sure air cannot
pass, to avoid stains on the wall, as often happens
with radiators)

20

- Fit the adjustable air vents. Apply the grill and fix

with silicone

21

- Wire up the control panel (see page 12)

148

90

60

9

8
10
6

12

13

11

5

1

3

14

18

14

Water

level

TRADUZIONE

Summary of Contents for AERJOLLY 100

Page 1: ...C A M I N E T T I S P A leader nel riscaldamento AERJOLLY WOOD BURNING FIREPLACE ASSEMBLY AND MAINTENANCE INSTRUCTIONS keep in a safe place PATENTED MODEL...

Page 2: ...onsulted whenever necessary as the directions it contains are important for safety during the installation use and maintenance of your fireplace Incorrect installation can lead to injury to people or...

Page 3: ...es Pag 5 Positioning of the air intake and electricity Pag 6 Positions to be followed during installation Pag 7 Assembly procedure Pag 8 9 Glasses assembly procedure Pag 10 Cladding Pag 11 Electrical...

Page 4: ...a room thermostat It also has a manually fed humidifier to avoid health problems such as a dry throat headaches various allergies etc fragrant balsamic essences can be added mixed with the water The f...

Page 5: ...lined to prevent the fumes from cooling and the consequent formation of condensation the same goes for the exposed section from the roof to the chimney pot We recommend using unlined stainless steel...

Page 6: ...ry panel 5 Rear refractory panel 6 Cast iron grille 7 Front sheet 8 Deflector 9 Fume register 10 Fume register push rod 11 Friction with screws and nogs 12 Humidifier topping up 13 Cap 1 2 14 Steel at...

Page 7: ...lexible pipe 100 80 120 100 10 Tube clamps 11 Glass wool blanket for air pipes 12 Rock wool blanket for flue 13 Box with automatic closure for external air intake 14 Box for external air intake holder...

Page 8: ...the wall by about 50 70 cm to allow for the electrical connections We recommend respecting the indicated measures If the fireplace is to have a side seat the electrical plant must be installed on the...

Page 9: ...70 Pag 7 C A M I N E T T I S P A leader nel riscaldamento POSITIONS TO BE FOLLOWED DURING INSTALLATION 60 78 60 88 60 108 78 79 21 88 91 28 108 102 28 WALL POSITIONING MOD 80 MOD 100 CORNER POSITIONI...

Page 10: ...tube with the top up fitting must run parallel with the boiler fitting The tank must be fixed on the inside or outside of the hood Extend the tube as required 15 Register friction 16 Fit the fume regi...

Page 11: ...ent forming a well polished funnel see example Otherwise make a hole in the flue see drawing 16 15 17 20 19 OFF MIN MED MAX ESTATE INVERNO 20 EXAMPLE OF FLUE WITH UNIVERSAL FITTING Flue Hole for walli...

Page 12: ...t close properly i e not aligned or one sticking out loosen the screw responsible for the misalignment and compensate with silicone FIREGUARD WITH DOORS AND LATCH DOORS OPTIONAL Apply a layer of sili...

Page 13: ...fit the air intakes 20x20 or diam 20 outside by using flexible pipes and creating an air intake under the fireplace connecting the internal room with outside to allow the ventilator to intake air fro...

Page 14: ...our local dealer or direct from the manufacturer Take great care when making all electrical connections through its devices Always insert properly The luminous led on the control panel is always on wh...

Page 15: ...of tube clamps These tubes must be insulated in order to guarantee top per formance of the fireplace These should thus be fully lined with glass wool blankets min 3 cm thick Never use plastic tubes to...

Page 16: ...f fibreglass Plumb as shown in the figure A door must be fitted on the left of the hood to allow for inspection of the valves and electrical coil The water temperature gauge must be built into the hoo...

Page 17: ...g grilles on air intakes which could stop the air flow It is advisable the use of a wide net AERJOLLY MAINTENANCE Routine and systematic upkeep is essential to ensure top efficiency and max heat outpu...