rdering Information

Table 2:  Ordering Information

Item

Description

RLD-H10G-1

Refrigerant leak detector with 120 VAC power cord

RLD-H10-100

14 in. flexible probe extension

RLD-H10-600R

Tune-up kit; includes sensor, 100 filters, 4 airflow indicator balls, 3 probe tips, and leak vial

RLD-H10-601R

Replacement sensor

RLD-H10-602R

Maintenance kit; includes 100 replacement filters, 4 airflow indicator balls, and 3 probe tips

RLD-H10-603R

Replacement leak vial (contains enough refrigerant to last approximately six months)

R

epair

Should it become necessary to repair your
RLD-H10G, please contact your Johnson
Controls/PENN representative.

Warranty Repairs

Units under warranty will be shipped to Johnson
Controls/PENN for repairs.  The repairs will be
completed within 24 hours after receipt by the repair
center, and the unit will be returned to your Johnson
Controls/PENN representative at the same priority of
shipment with which it was received.

Non-Warranty Repairs

Units that are no longer under warranty will be
repaired to factory specifications for a nominal fee.
The repairs will be completed within seven days after
receipt by the repair center, and the unit will be
returned to your Johnson Controls/PENN
representative at the same priority of shipment with
which it was received.

Summary of Contents for RLD-H10G

Page 1: ...mission Heated Diode Sensor Provides the most sensitivity available today while still detecting all halogenated refrigerant gases Halogen Selective Sensing Eliminates many sources of possible false alarms due to background contamination High Quality Air Pump Supplies constant air flow to sensor so it responds quickly to leaks also helps sensor recover quickly after exposure to refrigerant so leak ...

Page 2: ...on technology which is based on the ionization characteristics of alkali metals The alkali metals act as the cathode of a diode and the anode is heated by a DC voltage Air from the area being leak checked is pumped from the probe and into the space between the cathode and anode If halogen gas is present it creates an ionized current between the cathode and the anode which is amplified to sound a s...

Page 3: ...ch to on position See Figure 8 3 Slide range switch to small SM leak position See Figure 8 4 Check for sufficient airflow by pointing the probe tip toward the floor and observing the airflow ball in the probe See Figure 9 If the airflow is sufficient the ball will rise and float a small distance above the tip of the probe If the ball does not rise tap the probe lightly to make sure it is not stick...

Page 4: ...nd to the leak vial make sure there is liquid in the bottle If the unit still does not respond to the leak increase the sensor heat slightly by turning the sensor heat control knob on the bottom of the unit 1 16th of a turn clockwise 5 Allow a minute for the sensor to heat then repeat the calibration procedure Tips for Finding Leaks Use the black rubber probe tip whenever possible and hold the pro...

Page 5: ...emove the old airflow indicator ball 3 Insert the new airflow indicator ball into the probe 4 Reattach the probe end to the hose Figure 10 Replacing the Filter and Airflow Indicator Replacing the Sensor The sensor is a plug in unit that is thrown away when expended It needs replacement when the RLD H10G no longer responds to the leak vial even with the sensor heat control turned fully clockwise Ma...

Page 6: ...r RLD H10 602R Heat control set too low Increase the sensor heat slightly by turning the sensor heat knob on the bottom of the unit 1 16th of a turn clockwise Allow a minute for the sensor to heat then repeat calibration Audio normal probe lamp does not flash Burned out or damaged probe lamp Return unit to your Johnson Controls PENN representative Responds continuously in all leak positions Dirt i...

Page 7: ... Should it become necessary to repair your RLD H10G please contact your Johnson Controls PENN representative Warranty Repairs Units under warranty will be shipped to Johnson Controls PENN for repairs The repairs will be completed within 24 hours after receipt by the repair center and the unit will be returned to your Johnson Controls PENN representative at the same priority of shipment with which ...

Page 8: ...racy Meets SAE J1627 test requirements Probe Length Approximately 4 5 ft 1 4 m Ambient Operating Conditions 32 to 113 F 0 to 45 C 5 90 RH non condensing Ambient Storage Conditions 14 to 140 F 10 to 60 C 5 90 RH non condensing Case Vinyl Dimensions H x W x D 2 8 x 8 8 x 5 0 in 71 x 224 x 127 mm Shipping Weight 3 2 lb 1 4 kg Agency Listings UL Listed File SA9717 The performance specifications are no...