OPTIONAL PARTS
3-12
TC-18002
1
The following switches are on the IR receiver kit.
Turn OFF the power source completely before setting the DIP switch for the IR receiver kit.
Not doing so may result in an electric shock.
2
Emergency Operation Setting
“COOL” and “HEAT” switches are used for emergency operation when the batteries for the wireless
controller are low.
(1) Switch “COOL”: Press “COOL” so that the cooling operation is started.
Press “COOL” again so that the cooling operation is stopped.
(2) Switch “HEAT”: Press “HEAT” so that the heating operation is started.
Press “HEAT” again so that the heating operation is stopped.
NOTE:
During an emergency operation, a yellow light “
” flashes (0.5 second ON/0.5 second OFF).
The temperature set-point and the fan speed for the cooling/heating operation are the same as before
starting an emergency operation.
Review the following settings when the function for the IR receiver kit is selected from the wireless controller
or the centralized controller.
● The cooling lower limit for the temperature set-point and the heating upper limit for temperature set-point
are not available. The setting is available beyond the upper and lower limit for temperature set-point from
the wireless controller.
● The optional function setting “Fixing of Setting Temperature” is not available. When the operation mode
is changed from the wireless controller, the indicated temperature on the wired controller becomes the set
temperature of the wireless controller.
3
The DIP switch (DSW1) is for the optional function selection. If the optional function selection is required,
set the DIP switch as follows.
Optional Function
DIP Switch Setting (DSW1)
Details
1
2
3
4
5
6
Main/Sub Setting
O
X
X
X
X
X Change main (OFF setting)/sub (ON setting) wireless
controller for a two-wireless controller system.
Identification of
Indoor Unit
X
O
X
X
X
X
It functions as B Mode (identification of indoor unit) of
the wireless controller when it sets to “ON”.
Invalidity of
Emergency Operation
X
X
X
O
X
X The switches for emergency operation are invalid.
O: ON
X: OFF
3.7.6 Optional Functions
"COOL" Button
"HEAT" Button
PCB
Rear Side of IR Receiver Kit
Cover
DIP Switch (DSW1)
(Factory-Setting)
EMERGENCY
TIMER FILTER DEF RUN
HEAT
COOL
1 2 3 4 5 6
ON