John Lewis JLBIHD603 Instruction Manual Download Page 7

7

Extraction (Ducted)

T

he cooker hood is more e

ff

ecti

v

w

hen installed in the 

e

x

traction mode 

(

ducted to the outside

).

V

entin

g

 kits ma

y

 be 

p

urchased throu

g

y

our retailer or 

DI

Y

 store

,

 and must be e

v

acuated throu

g

h an outside 

v

ent o

f

 

ø125

 

(5

ins

)

 or 

ø15

0mm 

(

6ins

).

T

he ductin

g

 used must be manu

f

actured 

f

rom 

f

ire 

retardent material con

f

ormin

g

 to the rele

v

ant British 

S

tandard or DI

N

 4

1

0

2

-B

1.

When the cooker hood is ducted to the outside 
the charcoal filter must be removed.

 

 Fitting 

the 

Ducting

 

F

it the 

ø15

0mm 

(

6ins

)

 ductin

g

 to the s

p

i

g

ot on to

p

  o

f

 

the hood bod

y

 as illustrated

.

 

W

hen usin

g

 

ø125

mm 

(5

ins

)

 ductin

g

 

f

it 

item 9

 and 

10

 

on to the s

p

i

g

ot on the to

p

  o

f

 the hood bod

y

 as illus-

trated

.

 

F

or the best 

p

er

f

ormance use the shortest 

p

ossible run 

o

f

 ductin

g

 and 

w

e recommend the use o

f

 ri

g

id 

p

i

p

e in 

p

re

f

erence to 

f

le

x

ible hose as this 

w

ill im

p

ro

v

e the 

f

lo

w

 

o

f

 air 

w

hile reducin

g

 turbulence

,

 

w

hich causes noise and 

a loss o

f

 

p

er

f

ormance

.

  I

f

 the room 

w

here the cooker hood is to be used contains 

f

uel burnin

g

  a

pp

liance such as a central heatin

g

 boiler

,

 

then its 

f

lue must be be o

f

 the room sealed or balanced 

f

lue t

yp

e

.

  I

f

 other t

yp

es o

f

 

f

lue or a

pp

liances are 

f

itted ensure that 

there is an ade

q

uate su

pp

l

y

  o

f

 air to the room

.

 

T

he cooker ductin

g

 

w

hen 

f

itted in the e

x

traction mode 

must ne

v

er be connected to central heatin

g

 

f

lues

,

 radiators 

or 

w

ater heaters

.

Recirculation Mode

T

he cooker hood is su

pp

lied s

p

eci

f

ied 

f

or use in the recircula-

tion mode

,

 

w

ith the charcoal 

f

ilter 

f

itted

.

 

In the recirculation mode contaminated air is 

p

assed throu

g

the charcoal 

f

ilter to be 

p

uri

f

ied and recirculated into the kitch-

en throu

g

h the 

g

rille outlets on either side o

f

 the chimne

y.

 

A

ssemble the t

w

o hal

v

es o

f

 the ductin

g

  e

x

tension 

p

i

p

item 

1

4

.

 

P

ush-

f

it  the e

x

tension 

p

i

p

e on to the ductin

g

  s

p

i

g

ot on 

to

p

  o

f

 the cano

py.

 

P

ush-

f

it the recirculation ada

p

ter 

item

 

15

 on to e

x

tension 

p

i

p

item

 

14

.

  Insert the recirculation outlet e

x

tensions 

item 14.4

 into 

the recirculation ada

p

ter 

item

 

15

.

 

T

he recircualtion 

g

rilles 

item

 

8a

 and 

8b 

must be 

f

itted 

a

f

ter the lo

w

er chimne

y

 

item

 

2.2

 has been 

f

itted

.

 

E

nsure the acti

v

ated charcoal 

f

ilter has been 

f

itted

.

9

ø 150

ø 125

10

14

14.1

15

8a

8b

Summary of Contents for JLBIHD603

Page 1: ...JLBIHD603 JLBIHD904 built in cooker hood Instruction manual...

Page 2: ...g the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of f...

Page 3: ...nections 9 Electrical Requirements 9 Electrical Connection 9 Installing the Cooker Hood 5 Installation Requirements 5 Unpacking 5 Fitting the Wall Brackets 6 Fitting the Canopy Hood 6 Extraction 7 Rec...

Page 4: ...4 650 min 520 420 46 8 598 898 530 108 259 150 740 740 945 90 135 433 260 300 Description of the Appliance...

Page 5: ...he manufacturer disclaims any responsibility for dam age due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type...

Page 6: ...ove the hob and mark two hole centres at 116mm either side of the vetical line Drill 8 mm holes at all the centre points marked Insert the wall plugs not supplied in the holes Fix the brackets using t...

Page 7: ...ins a fuel burning appliance such as a central heating boiler then its flue must be be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an...

Page 8: ...stack item 2 1 and the canopy Secure the chimney stack to the canopy using the two screws item 12c 2 9 x 9 5mm supplied After the chimney has been secured into position insert the two plastic recircu...

Page 9: ...e the cooker hood Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan This applianc...

Page 10: ...red Recirculation In the recirculation mode the contaminated air enters the cooker hood through the grease filters The air is cleaned by passing through the charcoal filters before being passed back i...

Page 11: ...er when cleaning particularly around the control panel Metal Grease Filters The grease filters absorb grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned app...

Page 12: ...the filter replace the fixing hooks as illustrated This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended Changing the Light Bulb...

Page 13: ...ction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In the event of your appliance requiring servi...

Page 14: ......

Page 15: ......

Page 16: ...436002887_02 060227 John Lewis Partnership 171 Victoria Street London SW1E 5NN www johnlewis com 0306...

Reviews: