background image

11

 

Before carrying out any maintenance or lean-
ing isolate the cooker hood from the mains 
supply.

 

The cooker hood must be kept clean, as a 

build up of grease or fat can be a fire hazard.

Ex

ternal cleanin

g

W

i

p

e the cooker hood 

f

re

q

uentl

y

 

w

ith 

w

arm soa

py

 

w

ater 

usin

g

 a mild deter

g

ent

.

 

Never use scouring pads or abrasive cleaners.

 

Never use excessive amounts of water when 
cleaning particularly around the control panel.

M

etal 

G

rease 

F

ilters

T

he 

g

rease 

f

ilters absorb 

g

rease and dust durin

g

 cookin

g

 

to hel

p

 kee

p

 the cooker hood clean inside

,

 and should be 

cleaned a

pp

ro

x

imatel

y

 once e

v

er

y

 month or more o

f

ten 

i

f

 the hood is used 

f

or more than 3 hours a da

y.

 

R

emo

v

e the metal 

g

rease 

f

ilters 

one at a time b

y:

R

eleasin

g

 the catches on the 

f

ilters

,

 the 

f

ilters can be 

remo

v

ed

.

T

he metal 

g

rease 

f

ilters should be 

w

ashed

,

 b

y

 hand

,

 in mild 

soa

py

 

w

ater or in a dish

w

asher

.

 

A

llo

w

 to dr

y

 com

p

letel

y

 

be

f

ore re

p

lacin

g.

M

aintenance and 

C

leanin

g

Summary of Contents for JLBIHD603

Page 1: ...JLBIHD603 JLBIHD904 built in cooker hood Instruction manual...

Page 2: ...g the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of f...

Page 3: ...nections 9 Electrical Requirements 9 Electrical Connection 9 Installing the Cooker Hood 5 Installation Requirements 5 Unpacking 5 Fitting the Wall Brackets 6 Fitting the Canopy Hood 6 Extraction 7 Rec...

Page 4: ...4 650 min 520 420 46 8 598 898 530 108 259 150 740 740 945 90 135 433 260 300 Description of the Appliance...

Page 5: ...he manufacturer disclaims any responsibility for dam age due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type...

Page 6: ...ove the hob and mark two hole centres at 116mm either side of the vetical line Drill 8 mm holes at all the centre points marked Insert the wall plugs not supplied in the holes Fix the brackets using t...

Page 7: ...ins a fuel burning appliance such as a central heating boiler then its flue must be be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an...

Page 8: ...stack item 2 1 and the canopy Secure the chimney stack to the canopy using the two screws item 12c 2 9 x 9 5mm supplied After the chimney has been secured into position insert the two plastic recircu...

Page 9: ...e the cooker hood Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan This applianc...

Page 10: ...red Recirculation In the recirculation mode the contaminated air enters the cooker hood through the grease filters The air is cleaned by passing through the charcoal filters before being passed back i...

Page 11: ...er when cleaning particularly around the control panel Metal Grease Filters The grease filters absorb grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned app...

Page 12: ...the filter replace the fixing hooks as illustrated This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended Changing the Light Bulb...

Page 13: ...ction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In the event of your appliance requiring servi...

Page 14: ......

Page 15: ......

Page 16: ...436002887_02 060227 John Lewis Partnership 171 Victoria Street London SW1E 5NN www johnlewis com 0306...