5. Installation and start up
5.1. Installation
Do not install the machine near active heat sources (heaters, radiators, etc.). Avoid
obstructing the grids located at the front of the cabinet to ensure air circulation inside,
where the cooling unit motor is located (if the machine has one). Leave a distance of at
least 7 centimetres between the back of machine and the wall or other items.
IMPORTANT:
It is important for the machine to be level, as it should operate in
a vertical position, both laterally and front-to back, placed so the mains plug is readily
accessible and with a maximum tilt of
5% (~2°). This will also prevent noise and
vibration and will extend the cooling unit service life.
5.2. Start up
As a safety measure to avoid damaging the cooling circuit (if the machine has one), wait
to connect the machine to mains for 2 hours after finishing unpacking and installing the
machine.
VERY IMPORTANT:
To ensure the machine works properly it is essential that
the first reloading of the J-2000 compact take place through
address
25
(see the
manual for the compact), this should be done with at least three coins per tube, as
indicated on this manual.
5.3. Memory reset
In the standby menu without credit press the programming button
and when the
display shows the message
press key
.
The display will show a data enter menu with a message
.
To enter the key digits use pushbuttons
to
.
Use key
to cancel the digits you have entered, so you can enter a new key.
The master key to carry out the memory reset is
.
During reset, all memories are reset to zero except: prices, machine configuration and
the clock. The showcase light is programmed to always be on, the buzzer enabled,
single sales selected, coin return possible and maximum coin return set at the highest
value.
RESET PASSWORD:
PROGRAMMING
ADDRESSES