Joerns® Support Surface

FlapCair Model

© 2013 Joerns Healthcare • 6110066 RevD • 13-2631

Joerns Healthcare 1_Art Direction_Joerns Beds_700 Series_UltraCare 8page

4/2007_Page 4 of 8

3

Save These Instructions for Future 
Reference

Bed System Entrapment Information

Although essential in the practice of long-term care, 

bedside rails, in recent years, have also been a 

subject of regulatory review and evolution in design 

and use.

That focus includes not only the challenge of 

achieving an appropriate balance between resident 

security and unnecessary restraint, but also the 

additional safety issue of entrapment.

The U.S. Food and Drug Administration (FDA), 

working with our company and other industry 

representatives has addressed the potential danger 

of entrapment with new safety guidelines for medical 

beds. These guidelines recommend dimensional 

limits for critical gaps and spaces between bed 

system components.

Entrapment zones involve the relationship of 

components often directly assembled by the 

healthcare facility rather than the manufacturer. 

Therefore, compliance is the responsibility of the 

facility.

As the leading manufacturer of long-term care beds 

and a frontrunner in addressing this critical issue, 

Joerns Healthcare can offer you the expertise, 

assistance and products to bring your facility into 

compliance.

Joerns

®

 Compliance Solutions

Matching the right bed components in order to meet 

regulatory guidelines can be complex.

That is why Joerns offers a wide array of compliance 

options. We assist customers in selecting compliant 

accessories recommended for their specific bed 

model.

Creating a Safer Care Environment

While the guidelines apply to all healthcare settings, 

(hospitals, nursing homes and at home), long-term 

care facilities have particular exposure since serious 

entrapment events typically involve frail, elderly or 

dementia patients.

For More Information

To learn more about compliance options with Joerns 

products, visit our website at www.joerns.com, or 

contact our Customer Care reps at 800-826-0270 and 

ask for free informational publications.

To learn more about entrapment zones, assessment 

methods and guidelines concerning entrapment, 

contact Joerns Healthcare at 800-826-0270 or 

consult the FDA website:  http://www.fda.gov/

MedicalDevices/ProductsandMedicalProcedures/

GeneralHospitalDevicesandSupplies/HospitalBeds/

default.htm. 

Summary of Contents for FlapCair

Page 1: ...User Service Manual Joerns Support Surface FlapCair To avoid injury read user s manual before using...

Page 2: ...s Do not use in the presence of smoking materials or open flame Air flowing through the air mattress will support combustion 2 Danger To reduce the risk of shock adhere to the following instructions F...

Page 3: ...nufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joern...

Page 4: ...al Features 9 10 CPR Transport Power Failure CairRails Optional Accessories Troubleshooting 10 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures...

Page 5: ...gle caregiver installation featuring rapid inflation in just five minutes or less The user friendly controls allow for easy adjustment of patient comfort Additionally low friction and low shear materi...

Page 6: ...avoid unwanted or accidental adjustments Specially designed enclosure for low noise and durability Integrated swing out hanging brackets for fixing to most bed types 6 Therapy Mattress System Feature...

Page 7: ...e therapy pad is not already on the mattress place it on the mattress Attach the zippered cover to the mattress surround Hang the control unit on the foot of the bed facing away from the bed Attach th...

Page 8: ...at are mobile will need to be monitored to ensure they remain in the correct position to float the wound Operation Warning For important precautions please see page two Caution The patient s head shou...

Page 9: ...ve minutes Note The unit is designed to lock out all the adjustment controls after the patient has been positioned correctly In approximately five minutes after the last button push the power on light...

Page 10: ...ge Ready Valve for instant inflation and deflation Transfer friendly deflate for ease of assisted transfer or when bolsters are not required Unique contoured design allows ease of ingress egress while...

Page 11: ...incontinence barrier pad to absorb the excess moisture In the event of incontinence or excess drainage on the therapy pad you should wipe off the excess fluid from the bed surface 11 Safety Informatio...

Page 12: ...f there is no visible soilage with possible body fluids we recommend that you clean the mattress system with a mild detergent and warm water If disinfection is desired you may use a combination cleans...

Page 13: ...or Assistance If you have any questions or require service on a Joerns product please call Joerns Healthcare at 800 826 0270 Support Surface Gently roll up the support surface expelling any residual a...

Page 14: ...andling and or cleaning Failure to use in the manner indicated in the FlapCair user manual Any modification repair or alteration done to the FlapCair that was not authorized in writing by Joerns Healt...

Reviews: