Joerns Healthcare Warranty Program

  for Joerns

®

 FlapCair Support Surface

Post Acute, Acute, HomeCare

 

2430 Whitehall Park Dr. Ste 100

Charlotte, NC 28273

(P) 800.826.0270

(F) 800.457.8827

VA/Government

19748 Dearborn Street

Chatsworth, CA 91311

(P) 800.966.6662

(F) 800.232.9796

Canadian Office

1000 Clarke Rd. Ste 6

London, ON Canada N5V 3A9

(P) 866.546.1151

(F) 519.451.8662

United Kingdom and  

Other Countries

+44 (0)844 811 1156

+44 (0)844 811 1157

Netherlands

+31 (0)30 6363700

+31 (0)30 6363799

www.joerns.com • email: [email protected]

© 2013 Joerns Healthcare • 6110066 RevD • 13-2631

Joerns Healthcare warrants the FlapCair mattress 

to be sold free from defects in workmanship and 

materials, under normal and proper use, for a period 

of two (2) years on the mattress, and one (1) year on 

the cover and electromechanical mattress components 

(compressors, valves, printed circuit boards, hoses, 

and couplers). Damages arising from improper use will 

not be covered by this warranty. 

Improper use is defined as, but not limited to, those 

caused by:

• 

Burns 

• 

Use of improper chemical agents 

• 

Needle punctures, cuts, or abrasions 

• 

Excessive loads 

• 

Staining 

• 

Negligent or excessive usage 

• 

Improper maintenance, handling and/or cleaning 

• 

Failure to use in the manner indicated in the 

FlapCair user manual

Any modification, repair or alteration done to the 

FlapCair that was not authorized in writing by Joerns 

Healthcare will void this warranty.

Damage caused by use in unsuitable environmental 

conditions, abuse or failure to maintain the product in 

accordance with user and service instructions is not 

covered. 

This warranty is extended to the original purchaser of 

the equipment.

Parts

Joerns’s FlapCair contain various parts that wear from 

normal use. Joerns Healthcare’s obligation under this 

warranty is limited to supplying replacement parts, 

servicing or replacing, at its option, any product which 

is found by Joerns to be defective. When requested 

by Joerns, parts must be returned for inspection at the 

customer’s expense. Credit will be issued only after 

inspection.

Service

Most service requests can be handled by the facility 

Maintenance Department with assistance from the 

Joerns Healthcare Product Service Department. 

Most parts requested can be shipped next day air at 

the customer’s expense. 

Should a technician be required, one will be provided 

by Joerns Healthcare, at our discretion. Only the 

Joerns Healthcare Product Service Department can 

dispatch authorized technicians.

Manufactured by:

Joerns Healthcare, LLC

2100 Design Rd. Ste 100

Arlington, TX 76014

Summary of Contents for FlapCair

Page 1: ...User Service Manual Joerns Support Surface FlapCair To avoid injury read user s manual before using...

Page 2: ...s Do not use in the presence of smoking materials or open flame Air flowing through the air mattress will support combustion 2 Danger To reduce the risk of shock adhere to the following instructions F...

Page 3: ...nufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joern...

Page 4: ...al Features 9 10 CPR Transport Power Failure CairRails Optional Accessories Troubleshooting 10 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures...

Page 5: ...gle caregiver installation featuring rapid inflation in just five minutes or less The user friendly controls allow for easy adjustment of patient comfort Additionally low friction and low shear materi...

Page 6: ...avoid unwanted or accidental adjustments Specially designed enclosure for low noise and durability Integrated swing out hanging brackets for fixing to most bed types 6 Therapy Mattress System Feature...

Page 7: ...e therapy pad is not already on the mattress place it on the mattress Attach the zippered cover to the mattress surround Hang the control unit on the foot of the bed facing away from the bed Attach th...

Page 8: ...at are mobile will need to be monitored to ensure they remain in the correct position to float the wound Operation Warning For important precautions please see page two Caution The patient s head shou...

Page 9: ...ve minutes Note The unit is designed to lock out all the adjustment controls after the patient has been positioned correctly In approximately five minutes after the last button push the power on light...

Page 10: ...ge Ready Valve for instant inflation and deflation Transfer friendly deflate for ease of assisted transfer or when bolsters are not required Unique contoured design allows ease of ingress egress while...

Page 11: ...incontinence barrier pad to absorb the excess moisture In the event of incontinence or excess drainage on the therapy pad you should wipe off the excess fluid from the bed surface 11 Safety Informatio...

Page 12: ...f there is no visible soilage with possible body fluids we recommend that you clean the mattress system with a mild detergent and warm water If disinfection is desired you may use a combination cleans...

Page 13: ...or Assistance If you have any questions or require service on a Joerns product please call Joerns Healthcare at 800 826 0270 Support Surface Gently roll up the support surface expelling any residual a...

Page 14: ...andling and or cleaning Failure to use in the manner indicated in the FlapCair user manual Any modification repair or alteration done to the FlapCair that was not authorized in writing by Joerns Healt...