background image

 

 

9

Ⅱ、

LCD will show present frequency and volume of the radio after turning on the radio

 

Ⅲ、

In the working of radio

  The volumle of the present radio frequency

 

can be changed by pressing

 

MIN

and 

HOUR

 

Ⅳ、

Pressing the key

 “

SET

  will take out the memorized radio frequency

Pressing the key

 

SET

  continually will take out the memorized radio frequency from channels will be saved at present 

channel by pressing this key continually

If none of the channel

 LCD will display 

---

 

Ⅴ、

Press the key

 “

MEM

 ”

 could memorize the present radio frequency

 Pressing the key

 

MEM

  continually will memorize the present radio frequency in different channel

  The channel of max is 

10

Name of channel is 0-9

 

Ⅵ、

The volume can be changed by pressing key 

SET

VOL+

and

OPEN

 

11

Operation of Pump

 

The Button 

, operates pump 1

The Button  

PUMP2

operates  pump 2

The button 

PUMP3

operates pump 3

Also the pump 3 is the circulation pump

When pump 3 is turned on the LCD will show

 

”,

 whether the 

heating and circulation is on or off. 

T

he LCD will show 

w

hen pump3 is off and the 

heating, including pre-heating and circulation is about to start

 

12

Operation of lasting circulation cleaning

: 

Press the key 

  at any time to turn on or off the lasting circulation cleaning, work mode is like the 

preset circulation cleaning.    The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer 

works at every 15 minutes. 

  Once any surfing pumps or blower start, the ozonizer without working.    The ozonizer can not work if the 

circulation pump is without working.

   

 

IMPORTANT

: Please ensure that the ozone function is not in use whilst bathing in the spa 

13

Operation of spa lights

 

Press the

 

 button to 

control the ON/OFF of the LED lights 

For the first time pressing the key

  the LED lighting on

and the colours is changed slowly

For the second time pressing

the current colour unchange

For the third time pressing 

Off the lights

 

14

Setting the constant Temperature Settings

 

1

)、

Pressing the

 

 button 

will start the constant temperature heating. 

2

With the setting above, the circulation pump will work automatically. 

3

)、

If the temperature is set at 3

5℃,

 when the water temperature reaches or exceeds 3

6℃,

 the heater 

will be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature 

reaches or is lower than 3

4℃,

 the heater will start up again. 

Summary of Contents for SPA-8098

Page 1: ...1 HOT TUB Model SPA 8098 OPERATING INSTRUCTION ...

Page 2: ...g On off Surfing pump circulaltion pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with bule letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 Max with 3 surfing pumps 1circultion pump view pump and 1 blower 3 Set Ozone Set Spa lights 4 CD ...

Page 3: ...n cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE MEM the spa will become unlocked and the word LOCKED will disappear 3 Adjusting Time In the status Power off and the pre heating and circulation cleani...

Page 4: ...ning setting mode and the LCD showes and flashes and then the circulation workes on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stopping The adjustment range is 0 59 It will add 1 hour when pressing HOUR ea...

Page 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Page 6: ...s and enter Pre heating setting mode and the LCD flashes of ON Press can turn on the pre heating setting and pressing again will turn off the pre heating ON OFF on LCD will show ON and will not flash Press to turn off pre heating The LCD will show OFF without flashing When the system enters into pre heating mode the setting time will flash on the LCD this time is the pre heating time at this momen...

Page 7: ...When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time of pre heating is as same as current time the heater will start working off means the heater...

Page 8: ...on to Power ON OFF Pressing the key in power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig 9 10 AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Temperature setting In the status of Power on and HEATER is working It will add 1 centigrade by press each time the temperature will be added continu...

Page 9: ...d circulation is about to start 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulation cleaning The surfing pumps and blower work for 30 seconds at every 30 minutes Ozonizer works at every 15 minutes Once any surfing pumps or blower start the ozonizer without working The ozonizer can not wor...

Page 10: ...esistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x2 water pump AC220V 2HP x2 pump AC220v 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 1 Ozone Ozone 220V 240V 100W 1 water Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker 5 Warning Information a Means for disconnection must be incorporated in th...

Page 11: ...CTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited to cover the instrument with something while opeating 5 when u...

Page 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Reviews: