background image

 

 

12

 

Solutions of Fault

 

 

Phenomenon Reason How 

to Solve the problem 

No power supply 

1. The electric leakage switch

 

was 

breaked off 

2. The Fuse be break off 
 

1. Check and eliminate the malfunction, 

restart the spa 

2. Please change fuse 

No display on control 

panel 

 

1. The plug which connected with the 

panel loose or disconnected 

2. The Panel happened with malfunction 
 

1.

 

to connect the plug of the control 
panel and the main box 

2.

 

Change a new control panel 

LED light not work 

1.

 

Power of the light be break off 

2.

 

Fuse be break off 

3.

 

light be burn 

1.

 

To check if cable of the light is well 
connected with main box or not 

2.

 

Change a fuse 

3.

 

Change a new lampwick   

Ozone not work 

1.

 

Ozonater burn 

2.

 

Fuse be break off 

3.

 

Cable of the ozonater be cut off 

 

1.

 

Change a new ozonater 

2.

 

change a fuse 

3.

 

check if the cable of the main power 
is connected with the main box or 
not. 

Displaied “E1””FF” in 

control panel 

 

1. temperature detector be cut off or 

shortcirculate  

2. plug of the temperature detector be 

nundated by water 

 

1. Connect the temperature detector 
2.Change a new temperature detector 
 

being incapable of 

activate water pump,and 

water pump icon 

flashing 

 

 
1.water not achieve the appointed level 
2. water detector not connect well 
 

 
1.

 

To add more water to make it up to 
the water detector 

2.

 

To re-connect the line of water 
detector 

Heater not work, and 

heating icon on panel 

flashing 

 

1.

 

setting water temperature lower then 
the water temperature 

 

1.

 

set the temperature degrees higher 
than the water    in tub 
temperature(between 15 and 43 °C

Leakage 

1. silicon plaster not good   
2. PVC plaster not good 
3. Blow out of the water pipe 
 

1.

 

To remove the jets then re-install 
one 

2.

 

To plaster once again 
Change water pipe 

 
 

Summary of Contents for SPA-8098

Page 1: ...1 HOT TUB Model SPA 8098 OPERATING INSTRUCTION ...

Page 2: ...g On off Surfing pump circulaltion pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with bule letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 Max with 3 surfing pumps 1circultion pump view pump and 1 blower 3 Set Ozone Set Spa lights 4 CD ...

Page 3: ...n cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE MEM the spa will become unlocked and the word LOCKED will disappear 3 Adjusting Time In the status Power off and the pre heating and circulation cleani...

Page 4: ...ning setting mode and the LCD showes and flashes and then the circulation workes on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stopping The adjustment range is 0 59 It will add 1 hour when pressing HOUR ea...

Page 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Page 6: ...s and enter Pre heating setting mode and the LCD flashes of ON Press can turn on the pre heating setting and pressing again will turn off the pre heating ON OFF on LCD will show ON and will not flash Press to turn off pre heating The LCD will show OFF without flashing When the system enters into pre heating mode the setting time will flash on the LCD this time is the pre heating time at this momen...

Page 7: ...When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time of pre heating is as same as current time the heater will start working off means the heater...

Page 8: ...on to Power ON OFF Pressing the key in power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig 9 10 AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Temperature setting In the status of Power on and HEATER is working It will add 1 centigrade by press each time the temperature will be added continu...

Page 9: ...d circulation is about to start 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulation cleaning The surfing pumps and blower work for 30 seconds at every 30 minutes Ozonizer works at every 15 minutes Once any surfing pumps or blower start the ozonizer without working The ozonizer can not wor...

Page 10: ...esistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x2 water pump AC220V 2HP x2 pump AC220v 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 1 Ozone Ozone 220V 240V 100W 1 water Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker 5 Warning Information a Means for disconnection must be incorporated in th...

Page 11: ...CTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited to cover the instrument with something while opeating 5 when u...

Page 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Reviews: