background image

 

 

3

7

24 hours display and set time 

8

  Menoery preserve once power off 

9

Fahrenheit & Celsius degree switch 

10

Antifreezing functions 

11

Keys with backlight 

12

Lock settingl 

13

Three-phase or single-phase, available

 of 110-120VAC or 220-240VAC

   

14

Choice with 

offering a AC for circumscribing DVD or TV

 

15

Choice with power control 

16

Choice with galvanoscope device

 

 

III

Operation

 

             

 

Fig.3

Temperature Normal Display

                        Fig.4

Senor on/short circuit display

 

1

When you first start the spa, the backlight will be dimmed and the LCD will show the current time and 
temperature. If there is a problem with the circuit board the controller will display the code “E1”. When 
the radio frequency is displayed as 

---

 it indicates that the spa is in 

power off

 model, and 

pre-heating and circulation cleaning function is off. 

 

2

Lock memory Mode

(optional function)

 

The memory lock will start work by pressing

 

MEM

 key

 in the status of 

power off

when the 

spa has not been adjusted for a period of 30 minutes. When the memory locked key is pressed TWICE

 

MEM

  the spa will become 

unlocked and the word 

LOCKED

will disappear. 

3

Adjusting Time

 

In the status “Power off

 and the pre-heating and circulation cleaning are not starting. Pressing

 

MIN

or

HOUR

  adjust time . The Minute and Hour display flash at this time. It will add 1 hour when 

pressing

 

HOUR

  each time and the hours can be adjusted continually when pressing the 

HOUR

 

without stopping. The hour adjustment range is 

0-23.

 

In the status of time setting It will add 1 minute when pressing 

MIN

 

each time and the minutes 

could be added continually when pressing the

 

MIN

 

without stopping. The minute adjustment range is 

0~59 

The system will quit the time-setting status automatically after 6 seconds without pressing any buttons 

Summary of Contents for SPA-8098

Page 1: ...1 HOT TUB Model SPA 8098 OPERATING INSTRUCTION ...

Page 2: ...g On off Surfing pump circulaltion pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with bule letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 Max with 3 surfing pumps 1circultion pump view pump and 1 blower 3 Set Ozone Set Spa lights 4 CD ...

Page 3: ...n cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE MEM the spa will become unlocked and the word LOCKED will disappear 3 Adjusting Time In the status Power off and the pre heating and circulation cleani...

Page 4: ...ning setting mode and the LCD showes and flashes and then the circulation workes on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stopping The adjustment range is 0 59 It will add 1 hour when pressing HOUR ea...

Page 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Page 6: ...s and enter Pre heating setting mode and the LCD flashes of ON Press can turn on the pre heating setting and pressing again will turn off the pre heating ON OFF on LCD will show ON and will not flash Press to turn off pre heating The LCD will show OFF without flashing When the system enters into pre heating mode the setting time will flash on the LCD this time is the pre heating time at this momen...

Page 7: ...When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time of pre heating is as same as current time the heater will start working off means the heater...

Page 8: ...on to Power ON OFF Pressing the key in power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig 9 10 AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Temperature setting In the status of Power on and HEATER is working It will add 1 centigrade by press each time the temperature will be added continu...

Page 9: ...d circulation is about to start 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulation cleaning The surfing pumps and blower work for 30 seconds at every 30 minutes Ozonizer works at every 15 minutes Once any surfing pumps or blower start the ozonizer without working The ozonizer can not wor...

Page 10: ...esistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x2 water pump AC220V 2HP x2 pump AC220v 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 1 Ozone Ozone 220V 240V 100W 1 water Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker 5 Warning Information a Means for disconnection must be incorporated in th...

Page 11: ...CTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited to cover the instrument with something while opeating 5 when u...

Page 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Reviews: