MACHINE CONTROLS
Section 1
Page 1-11
1001206598
METRO-MH
11. Press the DOWN ARROW to
display a summary of the current
machine settings.
12. 10 seconds before engine start-up
an audible alarm sounds.
13. At the progammed starting-time the
engine will commence the pre-heat
cycle and, after 5 seconds the
starter-motor cranks the engine.
14. the controller setting allows the
engine to
“warm-up” for 10 seconds.
15. After co
mpleting engine ‘warm-up’,
each tower light is switched-on
sequenced at 3 second intervals.
16. The lighting tower will now run in the
AUTO MODE.
17. The following machine conditions will
cause the lighting tower to shut-
down when running in AUTOMODE.
•
Pushing the Emergency Stop button.
•
Opening the trailer canopy.
•
Pressing the STOP button on the
MH controller.
•
Triggering of the following engine
alarm conditions;
a) low oil pressure
b) low water level
c) high temperature
d) low fuel level
18. When the COUNTDOWN time has
elapsed all tower lights will be
switched-off in sequence.
19. The controller will allow the engine
a 20 second cooling cycle before