SECTION 3 - MACHINE OPERATION
1-877-254-3876
LIFTPOD by JLG
1001070451
1-877-2-LIFTPOD
www.liftpod.com
3-11
Charging the Batteries Using the Fast Charge Station
NOTE:
USE ONLY THE SUPPLIED CHARGING STATION.
1.
Remove battery from powerpack (Figure 3-14.).
2.
Place battery into recharging dock.
3.
Plug recharge dock into AC voltage wall outlet.
4.
Once the green LED has stopped flashing, the power-
pack is fully charged.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOL-
LOW THESE INSTRUCTIONS.
If the shape of the plug does not fit the power outlet, use an
attachment plug adaptor of the proper configuration for the power
outlet.
Unless the battery is being charged, always remove the battery
from the fast charger.
Fast Charge Indicator Light Guide
SOLID GREEN:
Insert battery or remove fully charged battery
Figure 3-14. Removing the battery from the powerpack
Pull and lift battery
release latch to
disengage battery
from powerpack
Figure 3-15. Recharge dock operations and indicators
Fault Indicator (RED)
Charge Indicator (GREEN)
Battery
Battery Release
Recharging Dock
FS.book Page 11 Wednesday, February 11, 2009 11:54 AM