SECTION 1 - MACHINE SPECIFICATIONS
1-2
– JLG Lift –
3121228
1.1 CAPACITIES
System Voltage
24 Volt DC
Hydraulic System
5 qts. U.S. (4.7 L)
Drive Motor GearBox (Gear Oil)
10 oz. (296cc)
1.2 COMPONENT DATA
Hydraulic Pump/Pump Motor Assembly
Pump Motor - 24 Volt DC motor, Standard Duty
Pump Displacement - .098 cu. in./rev. (1.6cc/rev.)
Pump Output (Max.) - 2.25 gpm @ 1400 psi @ 24 volts
and 105 amps @ 43 centistrokes (200 SSU)
Reservoir Capacity - 1 Gallon (3.78 L)
Rear Wheel Drive Motors
Drive Motors - 24 Volt DC, Variable
Gear Box - 3500 in.lb. (395.5 Nm) - Continuous Output
7000 in.lb. (791 Nm) - Intermittent Output
30.68:1 Gear Ratio
Brakes -
Friction Disk - Spring Applied - Electrically
Released
Batteries/Battery Charger
Batteries - 12 Volt DC (2 in series @ 24 volt)
6 Volt DC (4 in series @ 24 volt)
Nominal Capacity - 12V - 100 Amp Hour @ 20 Hr.
6V - 210 Amp Hour @ 20 Hr.
Type - M2 Marine Combination (AGM)/Valve Regulated/
Leak Proof/NonCorrosive/Maintenance Free
Weight -12V - 65.7 lb. (29.8 Kg) - Per Battery
6V - 64 lb. (29 Kg) - Per Battery
JLG MACHINES EQUIPPED WITH DELTA Q BATTERY CHARGERS
ARE DESIGNED FOR THE BEST PERFORMANCE WITH OEM FAC-
TORY APPROVED BATTERIES.
APPROVED JLG REPLACEMENT BATTERIES ARE AVAILABLE
THROUGH JLG' S AFTERMARKET PARTS DISTRIBUTION CEN-
TERS OR JLG' S AFTERMARKET PROGRAMS. FOR ASSISTANCE
WITH PROPER BATTERY REPLACEMENT, PLEASE CONTACT
YOUR LOCAL JLG SUPPORT OFFICE.
BATTERIES APPROVED BY JLG HAVE BEEN TESTED FOR COM-
PATIBILITY WITH THE ALGORITHM PROGRAMMING OF THE
DELTA Q BATTERY CHARGER TO OPTIMIZE BATTERY LIFE AND
MACHINE CYCLE TIMES. THE USE OF NON APPROVED BATTER-
IES IN YOUR JLG EQUIPMENT MAY RESULT IN PERFORMANCE
ISSUES OR BATTERY CHARGER FAULT CODES. JLG ASSUMES
NO RESPONSIBILITY FOR SERVICE OR PERFORMANCE ISSUES
ARISING FROM THE USE OF NON APPROVED BATTERIES.
Battery Charger -
Microprocessor Controlled/SCR Circuit Monitor
120/240 Volt A.C. Selectable / 50/60 Hz input
24 volt, 20 amp output - with 2 amp finish
Reset Circuit Breaker
Automatic Charge Circuit
Plug Interlock Circuit
NOTE:
The 10MSP batteries require approximately five (5)
hours to fully charge when drained to 80% discharge
- (Only the RED LEDS on platform console lit).
1.3 PERFORMANCE DATA
Platform Capacity
NOTE:
Distribute weight evenly in platform and material tray
when loading. Reference the capacity decal located
on the machines mast cover in the operators plat-
form.
Maximum Horizontal Manual Side Force
(Platform fully extended with Maximum load)
ANSI/CSA:
100 Lb. (445 N)
CE/AUST/JPN:
45 Lb. (200 N)
Platform Size
23 in.-W x 19.5 in.-L (58cm) x (49cm)
Material Tray Size
28.75 in.-W x 25.68 in.-L (73cm) x (65cm)
Platform Height - (Fully Elevated)
10 ft. (3.05m) - Standard (To floor of platform)
7 ft. (2.13m) - with Height Limiter (To floor of platform)
Platform Maximum (Working) Height
(Platform fully el Operator height)
16 ft. (4.92m) approximately
Table 1-2. Platform Maximum Capacity
SPECIFICATION
MAXIMUM CAPACITY
MAX. WIND
SPEED
Platform
Load
Material
Tray Load
Carry
Deck
ANSI/CSA
350 lb.
(160kg)
250 lb.
(115kg)
250 lb.
(115kg)
28 mph
(12 m/s)
CE
(Indoor Use Only)
0 m/s
Australia
(Indoor Use Only)
0 m/s