SECTION 6 - TROUBLESHOOTING
6-16
– JLG Lift –
3121228
6.9 SPECIFICATIONS FOR VARIOUS COMPONENTS
The following table contains specifications for machine components.
6.10 SPECIAL PIN EXTRACTOR TOOLS FOR ELECTRICAL CONNECTORS
The following table contains pin extractor tools for machine electrical connector components.
Table 6-2. Ohm Ratings for Various Components
COMPONENT
NOMINAL RESISTANCE @ TEMPERATURE
RESISTANCE RANGE POSSIBLE
Pump
Motor
0.2ohm
-
0.4ohm
@
77deg
F
0.12ohm
-
0.49ohm
Table 6-3. Amperage Draw for Various Components
COMPONENT
AMPERAGE
Ground Control Module
95 Amps @ room temperature with rated load
Traction Control Module
LEVEL SURFACE
(24V) (RATED LOAD)
15% GRADE
(24V) (RATED LOAD)
NO LOAD (24V)
7 to 11 Amps
(per motor)
55 to 60 Amps
(per motor)
3.5 to 4.8 Amps
78 to 86 RPM
Table 6-4. Special Pin Extractor Tools for Electrical Connectors
COMPONENT
DESCRIPTION
JLG PART NUMBER
ILLUSTRATION
Ground Control Station
For removal of electrical con-
nector pins from the Ground
Control Station connectors.
7016618
Drive Motor
For removal of electrical con-
nector pins from the Drive
Motor main power connec-
tors.
7002841
Drive Motor Brake
For removal of electrical con-
nector pins from the Drive
Motor Brake power connec-
tors.
7002842