20
JLA Limited
113372 - 16
ELECTRIC
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or
RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National
Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX. AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
208
1ø
2
24
123
—
175
220
1ø
2
20
98
—
125
230
1ø
2
22
97
—
125
240
1ø
2
24
107
108
150
208
1ø
2
30
152
—
200
220
1ø
2
26
125
127
175
230
1ø
2
28
123
130
175
240
1ø
2
30
132
133
175
220
1ø
2
20
—
100
150
230
1ø
2
22
—
104
150
208
3ø
3
24
74
—
100
220
3ø
3
20
60
61
80
230
3ø
3
22
56
63
80
240
3ø
3
24
65
66
90
208
3ø
3
30
91
—
125
220
3ø
3
30
86
—
125
220
3ø
3
26
76
77
100
230
3ø
3
28
71
78
100
240
3ø
3
30
79
—
100
416
3ø
4
30
49
50
70
380
3ø
4
20
—
39
50
400
3ø
4
22
—
40
60
416
3ø
4
24
—
41
60
240
3ø
3
30
—
80
125
380
3ø
4
26
—
48
70
400
3ø
4
28
—
48
70
208
3ø
3
24
71
—
90
220
3ø
3
20
57
57
80
240
3ø
3
24
63
63
80
380
3ø
3
20
33
—
50
440
3ø
3
20
29
—
40
460
3ø
3
22
30
—
40
480
3ø
3
24
32
—
50
208
3ø
3
30
88
—
125
220
3ø
3
26
73
73
100
240
3ø
3
30
77
78
100
380
3ø
3
26
42
—
60
440
3ø
3
26
37
—
50
460
3ø
3
28
38
—
50
480
3ø
3
30
39
—
50
230
3ø
3
22
—
60
80
380
3ø
4 or 3
20
—
33
50
400
3ø
4 or 3
22
—
35
50
416
3ø
4 or 3
24
—
36
50
230
3ø
3
28
—
75
100
380
3ø
4 or 3
26
—
43
60
380
3ø
4 or 3
30
—
49
70
400
3ø
4 or 3
28
—
44
60
416
3ø
4 or 3
30
—
45
60
440
3ø
4 or 3
26
—
37
50
b. Electric Models Only
ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data
label. The connecting wires must be properly sized to handle the rated current.
Check your local code for breaker and wire size
5/19/15