GAS AND STEAM
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
120
1ø
2
13
—
20
208
1ø
2
7.6
—
15
220
1ø
2
7.3
8.6
15
230
1ø
2
—
8
15
240
1ø
2
7
8
15
208
3ø
3
4.7
—
15
220
3ø
3
4.8
4.8
15
230
3ø
3
—
4.7
15
240
3ø
3
4.9
5.4
15
380
3ø
3
2.9
—
15
400
3ø
3
3
—
15
380 / 416
3ø
4 or 3
—
3.1
15
400
3ø
4 or 3
—
3.2
15
440
3ø
3
2.6
—
15
460 / 480
3ø
3
2.8
—
15
2. Electrical Service Specifications
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
a. Gas and Steam Models Only
Check your local code for breaker and wire size
5/19/15