Operating your Jindara Derwent
The Jindara Derwent Gas log space Heater has been designed for simple operation to provide you with the highest heat
output.
PRE-OPERATION CHECKS
Prior to operating the heater, ensure that the flue terminal is
not obstructed. Furthermore, make sure there are no
combustible objects leaning against, resting on, or within
the immediate vicinity of the unit. Check that the heater‘s
main power and gas supply are connected and switched on.
OPERATING THE HEATER
The heater can be operated by two different modes,
manually or by the thermostat remote controlled
hand held device .
Manual mode:
The controls are located on the right hand
side of the front lower false panel. The operation of the
buttons are as follows:
TURNING THE APPLIANCE ON (MANUAL MODE)
1.
To ignite your heater press the Ignition ON/OFF Button and the heater will automatically start the ignition
sequence. After approximated 30 seconds of pre-purge the heater will ignite.
2.
The heater will always start in the low heat setting and the heater will warm-up for at least 2 minutes before
automatically going to the higher flame setting.
3.
The fan will not start until the heater’s firebox has reached the minimum operating temperature. In High heat
setting the fan speed will be locked in high and can not be set to medium or low speed, unless the heat setting is
changed to medium or low. (This prevents overheating the heat exchanger.) NOTE: Turning on the thermostat
remote will override the manual operation of the heater! To go back to manual operation of the heater, the
thermostat remote needs to be off for 20 minutes before the control module will not look for any more signals from
the thermostat.
Read these instructions
Fan
speed
LED
indicators
Heat
setting
buttons
Fan
speed
setting
buttons
On/Off
Button
TURNING THE APPLIANCE OFF
Press the ON/OFF switch once. The room fan will continue to operate for a short period while the heater cools down.
Please note:
1.
This appliance cannot be operated without the fan running.
2.
Due to the performance and efficiency of the heater, steam may be noticed coming from the flue terminal on cool
days.
3.
As this appliance has a luminous effect some slight carbon deposition may occur.
4.
During first time firing of this appliance, an odour may be noticed for a short period of time while the paint cures. It
is advisable to leave the windows open during the first few hours of the very first operation only.
Derwent High Efficiency Gas Log Fire