II. Installation of manometer
II. Installation of manometer
III. Installation of control valve
1. Take out the manometer from the package,
check whether that the seal ring is present.
2. Screw the manometer onto the control
valve in a clockwise direction until tightly fixed.
1. Connect one end of a corrugated pipe (P18) to Port B, the other end to
port F of the pool. Secure tightly with a strap (P17).
2. Connect one end of the connecting pipe P12 to Port C of the control
valve, the other end to Port C of the motor. Secure tightly with the strap
1.Check whether the seal ring of the control valve (P5) is properly
positioned, then place the control valve (P2) onto the top of the body
slowly, and ensure the port at the bottom of the control valve is closely
inserted into the port on the top of the central connecting pipe (P9) (FIG.
06, 07).
2. There are 3 port connecting points on the control valve. It is essential to
ensure Port A points towards the pool, and that Port C of the control valve
is aligned with Port C of the motor. (See FIG. 10)
3. Remove the screw group on the control valve retainer, clamp the control
valve retainer around the flange between the body and the control valve,
and then pass the screw group through the drilled clip nuts and tighten
with a screwdriver (not provided) (see FIG. 08).