Jetter AG
Programming | 7
JX3-BN-EC User Manual
67 / 92
Index
Sub-
in-
dex
Description/
Name
Type
Type
of ac-
cess
0x8000
:0x19 Channel 2.Configuration.1. digital value
analog input
UDINT
RW
:0x1A Channel 2.Configuration.1. physical value
(min)
UDINT
RW
:0x1B Channel 2.Configuration.2. digital value
analog input
UDINT
RW
:0x1C Channel 2.Configuration.2. physical value
(max)
UDINT
RW
:0x1D Channel 2.Configuration.Offset of the lin-
ear equation y= mx+t
UDINT
RW
:0x1E Channel 2.Configuration.Offset actual
value (similar to a scale’s tare function)
UDINT
RW
:0x1F Channel 2.Configuration.Sensor Sensitiv-
ity
UDINT
RW
0xA000
Status Module:JX3-DMS2
:0x00 SubIndex 000
USINT
RO
:0x01 Diagnostics..State
UDINT
RO
:0x02 Module.Modulediagnostics.State
UDINT
RO
:0x03 Module.Modulediagnostics.Valid Bit
BOOL
RO
:0x04 Module.Modulediagnostics.Short cut
power supply sensor 1 or 2
BOOL
RO
:0x05 Module.Modulediagnostics.Channel1 or
Channel2 measurement value below
lower sw limit
BOOL
RO
:0x06 Module.Modulediagnostics.Channel1 or
Channel2 measurement value above up-
per sw limit
BOOL
RO
:0x07 Module.Modulediagnostics.Forcing of
channel 1 OR channel 2 enabled
BOOL
RO
:0x08 Module.Modulediagnostics.Voltage Moni-
tor of internal voltages is activated
BOOL
RO
:0x09 Module.Modulediagnostics.synchronized
data exchange with plc
BOOL
RO
:0x0A Channel 1.Diagnostics.State
UDINT
RO
:0x0B Channel 1.Diagnostics.Tare activated
BOOL
RO
:0x0C Channel 1.Diagnostics.Measurement re-
sult valid
BOOL
RO
:0x0D Channel 1.Diagnostics.Unipolar mode ac-
tive
BOOL
RO
:0x0E Channel 1.Diagnostics.Ultrafastmode ac-
tive
BOOL
RO
:0x0F Channel 1.Diagnostics.Veryfast mode ac-
tive
BOOL
RO
:0x10 Channel 1.Diagnostics.Fast mode active
BOOL
RO
:0x11 Channel 1.Diagnostics.Slow mode active
BOOL
RO
:0x12 Channel 1.Diagnostics.Calibration data
active
BOOL
RO
:0x13 Channel 1.Diagnostics.Forcemode active
BOOL
RO
:0x14 Channel 1.Diagnostics.Very slow mode
active
BOOL
RO