JetMove 204-480
7.1 Power Supply Connection
Jetter AG
45
7
Description of Connections
7.1
Power Supply Connection
Specification of Terminal X1
• 4-pin male connector; screw connection (type: Phoenix PC 6/4-ST-10,16)
• Allowed conductor size: max. 0.5 ... 6 mm
2
(AWG 20 ... 7)
• Torque: 1.2 ... 1.5 Nm (10.6 ... 13.3 lbf-inch)
• Ambient temperature: max. 45 °C
• Field wiring
Specifications of Connecting Cable
• Cable size: min. 4 * 1.0 mm² (AWG 18)
• Material: Copper
• Temperature class: 60 °C
Shielding
• Not required
Fig. 8: Power supply connection
Power Supply
Amplifier Field
Wiring Terminal X1
Power Lines
Specification
U1
L1
• AC 400 ... 480 V
between the power lines
V1
L2
W1
L3
PE (GND)
PE / GND conductor
U1
V1
W
1
PE
yellow / green
PE
Core 3
Line voltage 3
Core 2
Line voltage 2
Core 1
Line voltage 3
X1