JetMove 204-480
3 Operating Conditions
Jetter AG
31
Additional line filters can be helpful here. See "Line filter" on page 36.
EMC
Emitted Interference
Parameters
Value
Reference
Enclosure
• Frequency band
30 ... 230 MHz, limit 30 dB (
μ
V/
m) at 30 m
• Frequency band
230 ... 1,000 MHz, limit 37 dB
(
μ
V/m) at 30 m
(class B)
DIN EN 61800-3
Mains alternating
current
• Frequency band
0.15 ... 0.5 MHz, limit 79 dB(
μ
V)
• Frequency band
0.5 ... 30 MHz, limit 73 dB(
μ
V)
DIN EN 61800-3
Important!
This is a product of restricted availability according to IEC/EN 61800-3.
This module can cause radio interferences in residential areas; in this
case, the user must take adequate measures to prevent this.
EMC
Interference Immunity: Enclosure
Parameters
Value
Reference
RF Field, amplitude-
modulated
Frequency band
80 ...1,000 MHz;
test field strength 10 V/m
AM 80 % with 1 kHz
Criterion A
DIN EN 61000-4-3
DIN EN 61800-3
ESD
Contact discharge:
Test peak voltage 6 kV
Criterion B
DIN EN 61800-3
DIN EN 61000-4-2
Summary of Contents for JM-204-480
Page 1: ...User Manual JM 204 480 Digital Servo Amplifier 60870618 We automate your success...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...82 Jetter AG...
Page 86: ...86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 204 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...