Jetter AG
Identification and Configuration | 7
User Manual – JCM-501-E01
26 / 65
Carrying out the
update
JetEasyDownload –H100 –T127 –B5 –S8000 –Ljcm_ce0_X.XX.X.XX.os
ü
JetEasyDownload and PEAK CAN dongle are ready for use.
ü
There is a CAN connection between PEAK CAN dongle and JCM-501-E01.
1.
Call up JetEasyDownload with the above parameters and a valid OS file.
ð
The device carries out a reset.
ð
The device starts in boot loader mode with a single heartbeat in init state
(data = 0x00).
2.
Wait for approx. 7 seconds while the device formats the flash memory.
ð
The device starts the download process.
ð