USB port
NOTICE
The USB port does not meet the immunity requirements
relevant for KBA E1 approval.
►
Use the USB port for service purposes only.
►
Do not use the USB port while the unit is in operation.
Parameter
Description
Supply unit
5 V, max. 500 mA
Data rate
USB 2.0
High-speed type
480 MBaud max.
Protocol
USB host interface
Line length limitation
30 cm
Tab. 6:
USB port
RS-232 interface
Parameter
Description
Baud rates
Up to 115,200 Baud
8N1
Connection topology
1x Deutsch connector socket
Tab. 7:
RS-232 interface specification
4.4 Environmental conditions
Parameter
Description
Standards
Operating temperature
-20 °C ... +65 °C
ISO 16750-4
Climatic conditions
Humid heat
Storage temperature
-20 °C ... +70 °C
ISO 16750-4
DIN EN 60068-2-1
DIN EN 60068-2-2
Relative humidity
10 % … 95 %
DIN EN 61131-2
Pollution degree
2
DIN EN 61131-2
Tab. 8:
Environmental conditions
4.5 Acoustic signal generator
Parameter
Description
Type
Loudspeaker
Adjustable frequency and
volume.
Volume
83 dB
10 cm distance and reso-
nance frequency
2,670 Hz
Tab. 9: