4
PI-078
June 2021
GENERAL WATERBLAST
1. Use only clear, clean water in high pressure system.
2. Place barricades with warning signs or barricade tape around work
area.
3. Outfit all operators with Personal Protective Equipment (PPE). Hard
hat with plastic face shield, rainsuit, non-skid knee boots
with metatar-
sal protection
, gloves, ear protection and body armor rated for operating
pressures are considered minimum safety equipment. Proper respiratory
protection is required where dangerous fumes or dust is present or
created by the waterblasting operation. Follow applicable OSHA
regulations, standards and guidelines regarding the use of respiratory
protection if harmful fumes or dust is present during, or created by the
waterblasting operation
4. Use products intended for high pressure waterblasting only.
5. No product should be altered
without written consent of the
manufacturer.
6. Read and follow all manufacturer’s instructions
prior to using any
waterblast product. Contact manufacturer.
7. Thoroughly review alternative methods before initiating any potential-
ly dangerous waterblasting operation. Fully automated, semi-automated,
and/or mechanized methods should all be considered first. Contact the
applicable waterblasting manufacturers for assistance and recommen-
dations.
8. The operator handling the cleaning device (with nozzle) must always
have control of water pressure. A surface cleaning operator should
operate a trigger style control gun capable of instantaneously stopping
pressure to nozzle. A tube cleaning lance operator should operate a foot
gun capable of instantaneously stopping pressure to the lance.
9. Inspect the condition of all components prior to use. Use no items
which are in questionable condition.
10. Check the condition of thread connections prior to the make-up of
any high pressure connection. Use Teflon tape and anti-seize on male
pipe (NPT) thread for sealing purposes. Do not let tape overlap the male
pipe thread end. Tape fragments may enter system water stream and
clog nozzle’s orifices.
Do Not use a component with missing or damaged threads on the
high pressure connections.