18
PI-078
June 2021
1. New Rotomag X22 comes with nozzle plugs installed. Determine
nozzle configuration to be used and remove plugs (if needed) using a
3/16” hex key.
2. For Rotomag X22 (1/2”-28 UNEF): If plugs are to be used, apply anti-
seize compound to male threads and install into correct ports using
3/16” hex key. Tighten to 50 lbs. in.
For Rotomag X22N (1/4” NPT): If plugs are to be used, apply 3-4
wraps of Teflon thread sealant tape to male connection thread. Apply
anti-seize compound over the sealant tape and install into correct
ports using 3/16” hex key. Tighten connection 1-1/2 to 2 turns past
hand tight.
3. For Rotomag X22: Apply anti-seize compound to male threads of
nozzles and install using 3/16” hex key. Tighten to 50 lbs. in.
For Rotomag X22N: Apply 3-4 wraps of Teflon thread sealant tape to
male connection thread. Apply anti-seize compound over the sealant
tape install using 3/16” hex key. Tighten connection 1-1/2 to 2 turns
past hand tight.
4.2 An anti-withdrawal device (backout preventer) should be used to
prevent the tool from accidently exiting the pipe under high pressure.
Hose restraints (whip checks) should be used at all high pressure hose
connections including the fluid end discharge. See Appendix B for a list of
backout preventers.
4.3 Contact Jetstream representative for assistance.